Indesit KP902GX Guía Del Usuario

Descargar
Página de 16
5
GB
Table of burner and nozzle specifications
Table 1
Liquid Gas
Natural Gas
Burner
Diameter
(mm)
Thermal Power
kW (p.c.s.*)
By-Pass
1/100
Nozzle
1/100
Flow*
g/h
Nozzle
1/100
Flow*
l/h
Nominal
Reduced
(mm)
(mm)
***
**
(mm)
Fast
(Large)(R)
100
3,00
0,7
40
86
218
214
116
286
Semi Fast
(Medium)(S)
75
1,65
0,4
30
64
120
118
96
157
Auxiliary
(Small)(A)
55
1,00
0,4
30
50
73
71
71
95
Triple Ring
(TC)
130
3.25
1.3
57
91
236
232
124
309
Supply
Pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25
*
At 15°C and 1013 mbar - dry gas
**
Propane P.C.S. = 50.37 MJ/kg
***
Butane P.C.S. = 49.47 MJ/kg
Natural P.C.S. = 37.78 MJ/m³
TECHNICAL DATA (1
st
 Oven ) 
Oven dimensions 
 
H:34;W:38;D:44 cm
 
Volume 
 
54 Lt
 
Burners
 
may be adapted for use with any 
type of gas shown on the data 
plate
 
Voltage and frequency
 
see data plate
 
ENERGY LABEL
 
Directive 2002/40/EC on the 
label of electric ovens.  
Regulation EN 50304  
 
Energy consumption for Natural 
convection – heating mode:  
              Traditional mode
;
  
 
Declared energy consumption 
for Forced convection Class – 
heating mode: 
              
Baking Mode. 
 
 
EC Directives: 2006/95/EEC 
dated 12/12/06 (Low Voltage) 
and subsequent amendments - 
89/336/EEC dated 03/05/89 
(Electromagnetic Compatibility) 
and subsequent amendments - 
90/369/EEC dated 29/06/90 
(Gas) and subsequent 
amendments - 93/68/EEC 
dated 22/07/93 and subsequent 
amendments - 2002/96/EC.
 
 
TECHNICAL DATA (2
nd
 Oven) 
Dimensions 
 
H:33.8;W:24.5;D:43.8 cm
 
Volume 
 
36 l
 
Burners
 
may be adapted for use with any 
type of gas shown on the data 
plate
 
Voltage and frequency
 
see data plate
 
ENERGY LABEL
 
Directive 2002/40/EC on the 
label of electric ovens.  
Regulation EN 50304  
 
Energy consumption for Natural 
convection – heating mode:  
              Traditional mode
;
  
 
 
EC Directives: 2006/95/CEE 
dated 12/12/06 (Low Voltage) 
and subsequent amendments - 
89/336/EEC dated 03/05/89 
(Electromagnetic Compatibility) 
and subsequent amendments - 
90/369/EEC dated 29/06/90 
(Gas) and subsequent 
amendments - 93/68/EEC 
dated 22/07/93 and subsequent 
amendments - 2002/96/EC.