Turn the knob to minimum and make sure (with the
door closed) that the flame became smaller, but stable
(about 3 o 4 mm). If the flame is not stable on the
minimum setting, remove the knob, unscrew the screw
from the control panel and remove it. Turn the screw
M” to adjust the thermostat minimum, turning it
counter-clockwise if the flame is too low and clockwise
if the flame is too high (Fig. G).
c) The grill burners has no regulation of the minimum.
N.B.: in the case of liquid gas, the regulation screw must
be screwed in to the bottom.
Check that the flame does not turn off when you turn the
tap quickly from high to low.
Attention: on completion of the above operation, please
replace the current technical data label with a new one
containing details of the gas which the appliance has now
been converted to. The new technical data label is
contained in the nozzles Kit supplied with the cooker.
Note: should the pressure of the gas used be different (or
vary) from the recommended pressure, it is necessary to
fit a suitable pressure regulator onto the inlet pipe in
compliance with current National Regulations relative to
“regulators for channelled gas”.
Burner and nozzles characteristics
Table 2
Liquid Gas
Natural Gas
Burner
Diameter
(mm)
Thermal power
kW
(p.c.s.*)
By-pass
1/100
(mm)
Nozzle
1/100
(mm)
Flow*
g/h
Nozzle
1/100
(mm)
Flow*
l/h
Nomin.
Reduc.
***
**
Front-Right
90
3.30
0.70
42
90
240
236
135
314
Rear-Left
78
2.70
0.70
42
83
196
193
122
257
Front-Left
50
1.70
0.40
29
65
124
121
97
162
Rear-Right
50
1.70
0.40
29
65
124
121
97
162
Oven
-
3.35
1.20
53
90
244
239
135
319
Grill
-
2.20
-
-
78
160
157
117
209
Supply
pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
37**
25**
45**
28-30***
20***
35***
20
17
25
*
At 15°C and 1013 mbar-dry gas
**
Propane
P.C.S. = 50,37 MJ/Kg
***
Butane
P.C.S. = 49,47 MJ/Kg
Natural
P.C.S. = 37,78 MJ/m
3
Technical characteristics
Mains frequency and voltage of the electric section and characteristics of the gas section
Model
Gas section
Electric section
Class
Rated power
kW (1)
Voltage
Power
(W)
KG 6407 BG/G
KG 6407 WG/G
KG 6407 XG/G
II2H3+
11,88 (864 g/h - G30)
(848 g/h - G31)
220-240V~ 50-60Hz
19
(1) The values in g/h refer to the capacities with liquid gas (Butane, Propane).