HP 350 470065-147 Manual De Usuario

Los códigos de productos
470065-147
Descargar
Página de 47
HP 1200W Power Supply
Part Number - AC
500172-B21
Operational Input Voltage Range
(Vrms)
100 to 240
Frequency Range (Nominal) (Hz)
50/60
Nominal Input Voltage (Vrms)
100
120
208
200
220
230
240
Maximum Rated Output Wattage
800
900
1200
1200
1200
1200
1200
Nominal Input Current (A rms)
9.7
9.0
7.0
6.8
6.4
9.1
5.9
Max Rated Input Wattage Rating
(Watts)
930
1034
1348
1348
1348
1348
1348
Max. Rated VA (Volt-Amp)
970
1079
1406
1406
1406
1406
1406
Efficiency (%) at Max. Rated Output
Wattage
86
87
89
89
89
89
89
Power Factor
0.97
0.97
0.97
0.97
0.97
0.97
0.97
Leakage Current (mA)
0.42
0.50
0.83
0.87
0.92
0.96
1.00
Max. Inrush Current (A peak)
30
30
30
30
30
30
30
Max. Inrush Current duration (mS)
20
20
20
20
20
20
20
Maximum British Thermal Unit
Rating (BTU-Hr)
3174
3530
4600
4600
4600
4600
4600
 
NOTES:
Prior to making a power supply selection it is "highly recommended" that the "HP Power Advisor" is run to determine the right size
power supply for your server configuration.
The HP Power Advisor is located at " 
 "
NOTE: Option Kits contain optional power supply, an IEC power cable and PDU IEC cables.
QuickSpecs
HP ProLiant ML350 Generation 6
Power Specifications
DA - 13241   Worldwide QuickSpecs — Version 8 — 7.15.2009
Page 43