Xantrex Technology C40R/50 Manual De Usuario

Descargar
Página de 34
18
975-0123-01-01 Rev A
Resetting the Amp-Hour Meter 
To manually reset the amp-hour meter, press and hold the push-button 
on the front of the meter until the display resets.
The meter automatically resets if power is disrupted (for example, DC 
cable is removed and replaced).
Turning the Display Backlight On or Off
Press and release the Amp-hour Reset button to turn the backlight 
on or off. 
6 Troubleshooting
If using long cable runs on the remote (greater than 100 feet) or if the 
meter seems inaccurate, remove the jumper located below the voltage 
configuration pins on the circuit board on the back of the unit. This dims 
the LCD backlight, reduces power consumption, and improves meter 
accuracy.
See the Owner’s Manual for the C-Series Multifunction DC Controller 
for additional information about Troubleshooting.