Goodman Mfg Multi-Position Manual De Usuario

Descargar
Página de 16
SS-GMV95  
www.goodmanmfg.com 
3
P
RODUCT
 S
PECIFICATIONS
S
PECIFICATIONS
GMV95 
0453BXB
GMV95 
0704CXB
GMV95 
0905DXB
GMV95-
1155DXB
GCV9 
0704CXB
GCV9 
0905DXB
GCV9
1155DXA 
Heating Capacity
High Fire Input¹
46,000
69,000
92,000
115,000
69,000
92,000
115,000
High Fire Output¹
45,000
67,000
90,000
109,000
65,000
87,000
109,000
Low Fire Input¹
32,000
48,000
64,000
80,000
48,000
64,000
80,000
Low Fire Output¹
30,800
46,400
61,700
77,400
45,000
60,100
77,400
AFUE²
95
95
95
95
93
93
93
Tons AC @ 0.5” ESP
1.5 - 3.0
1.5 - 4.0
2.0 - 5.0
2.0 - 5.0
1.5 - 4.0
2.0 - 5.0
2.0 - 5.0
Temperature Rise Range (°F)
30 - 60
30 - 60
30 - 60
30 - 60
30 - 60
30 - 60
40-70
Circulator Blower
Size (D x W)
10” X 7”
10” X 10”
11” X 10”
11” X 10”
10” x 10”
11” X 10”
11” X 10”
Horespower @ 1750 RPM
½
¾
1
1
¾
1
1
Speed
Variable
Variable
Vent Diameter³
2”
2”
3”
3”
2”
3”
3”
No. of Burners
2
3
4
5
3
4
5
Filter Size (in²)
Disposable
288
384
480
486
384
480
486
Permanent
576
768
960
972
768
960
972
Electrical Data
Min. Circuit Ampacity (amps)
4
10.4
12.8
14.6
14.6
12.8
14.6
14.6
Max. Overcurrent Protection
5
15 amps
15 amps
15 amps
15 amps
15 amps
15 amps
15 amps
Ship Weight (lbs)
133
135
172
175
135
172
175
1–  Natural Gas BTU/h
2–  DOE AFUE based upon Isolated Combustion System (ICS)
3–  Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the fl ue outlet (required). Vent pipe must 
be either 2” or 3” in diameter, depending upon furnace input, number of elbows, length of run and installation (1 or 2 pipes). The 
optional Combustion Air Pipe is dependent on installation/code requirements and must be 2” or 3” diameter PVC.
4–  Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with 
National Electrical Codes. Extensive wire runs will require larger wire sizes.
5–  Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type 
circuit breakers of the same size as noted.
Notes:
•  All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.
•  Gas Service Connection ½” FPT
•  Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code 
and/or all existing local codes.