6 www.goodmanmfg.com 
SS-GMV95
P
RODUCT
 S
PECIFICATIONS
GMV95 H
IGH
OR
 S
INGLE
-S
TAGE
 C
OOLING
 S
PEEDS
GMV95 L
OW
-S
TAGE
 C
OOLING
 S
PEEDS
GMV950453BXB
GMV950704CXB
GMV950905DXB
GMV951155DXB
Cooling
Speed Tap
Adjust
Tap
CFM¹
Cooling
Speed Tap
Adjust
Tap
CFM¹
Cooling
Speed Tap
Adjust
Tap
CFM¹
Cooling
Speed Tap
Adjust
Tap
CFM¹
A
Minus (-)
540
A
Minus (-)
540
A
Minus (-)
720
A
Minus (-)
720
Normal
600
Normal
600
Normal
800
Normal
800
Plus (+)
660
Plus (+)
660
Plus (+)
880
Plus (+)
880
B
Minus (-)
720
B
Minus (-)
720
B
Minus (-)
990
B
Minus (-)
990
Normal
800
Normal
800
Normal
1,100
Normal
1,100
Plus (+)
880
Plus (+)
880
Plus (+)
1,210
Plus (+)
1,210
C
Minus (-)
900
C
Minus (-)
990
C
Minus (-) 1,260
C
Minus (-) 1,260
Normal
1,000
Normal
1,100
Normal
1,400
Normal
1,400
Plus (+)
1,100
Plus (+)
1,210
Plus (+)
1,540
Plus (+)
1,540
D
Minus (-) 1,080
D
Minus (-) 1,286
D
Minus (-) 1,620
D
Minus (-) 1,620
Normal
1,200
Normal
1,429
Normal
1,800
Normal
1,800
Plus (+)
1,320
Plus (+)
1,572
Plus (+)
1,980
Plus (+)
1,980
¹  @ .1” to .8” W.C. ESP
Notes:
•   All furnaces ship as high speed for cooling.  Installer must adjust blower speed as needed.
•  For most jobs, about 400 CFM per ton when cooling is desirable.
•  Do not operate above .5” w.c. ESP in heating mode. Operating CFM between .5” and .8” w.c. is tabulated for cooling purposes only.
•  Constant Fan mode is 50% of above values
GMV950453BXB
GMV950704CXB
GMV950905DXB
GMV951155DXB
Cooling
Speed Tap
Adjust
Tap
CFM¹
Cooling
Speed Tap
Adjust
Tap
CFM¹
Cooling
Speed Tap
Adjust
Tap
CFM¹
Cooling
Speed  
Tap
Adjust
Tap
CFM¹
A
Minus (-)
380*
A
Minus (-)
378*
A
Minus (-)
513*
A
Minus (-)
514*
Normal
390
Normal
390
Normal
520
Normal
520
Plus (+)
429
Plus (+)
429
Plus (+)
572
Plus (+)
572
B
Minus (-)
468
B
Minus (-)
468
B
Minus (-)
644
B
Minus (-)
644
Normal
520
Normal
520
Normal
715
Normal
715
Plus (+)
572
Plus (+)
572
Plus (+)
787
Plus (+)
787
C
Minus (-)
585
C
Minus (-)
644
C
Minus (-)
819
C
Minus (-)
819
Normal
650
Normal
715
Normal
910
Normal
910
Plus (+)
715
Plus (+)
787
Plus (+)
1,001
Plus (+)
1,001
D
Minus (-)
702
D
Minus (-)
836
D
Minus (-) 1,053
D
Minus (-) 1,053
Normal
780
Normal
929
Normal
1,170
Normal
1,170
Plus (+)
858
Plus (+)
1,022
Plus (+)
1,287
Plus (+)
1,287
¹  @ .1” to .8” W.C. ESP
Notes:
•  All furnaces ship as high speed for cooling.  Installer must adjust blower speed as needed.
•  For most jobs, about 400 CFM per ton when cooling is desirable.
•  Do not operate above .5” w.c. ESP in heating mode. Operating CFM between .5” and .8” w.c. is tabulated for cooling purposes only.