SS-GMV95  
www.goodmanmfg.com 
9
P
RODUCT
 S
PECIFICATIONS
GCV9 C
OOLING
 S
PEEDS
GCV90704CXA
Cooling 
Speed 
Tap
Adjust
Tap
CFM at .1” to .8” w.c. ESP
Low Stage
High/Single-
Stage
A
Minus (-)
378*
540
Normal
390
600
Plus(+)
429
660
B
Minus (-)
468
720
Normal
520
800
Plus(+)
572
880
C
Minus (-)
644
990
Normal
715
1,100
Plus(+)
787
1,210
D
Minus (-)
836
1,286
Normal
929
1,429
Plus(+)
1,022
1,572
GCV90905DXA
Cooling 
Speed 
Tap
Adjust
Tap
CFM at .1” to .8” w.c. ESP
Low Stage
High/Single-
Stage
A
Minus (-)
513*
720
Normal
520
800
Plus(+)
572
880
B
Minus (-)
644
990
Normal
715
1,100
Plus(+)
787
1,210
C
Minus (-)
819
1,260
Normal
910
1,400
Plus(+)
1,001
1,540
D
Minus (-)
1,053
1,620
Normal
1,170
1,800
Plus(+)
1,287
1,980
GCV91155DXA 
Cooling 
Speed 
Tap
Adjust
Tap
CFM at .1” to .8” w.c. ESP
Low Stage
High/Single-
Stage
A
Minus (-)
500*
705
Normal
508
783
Plus(+)
559
861
B
Minus (-)
621
982
Normal
690
1,091
Plus(+)
759
1,200
C
Minus (-)
815
1,265
Normal
906
1,406
Plus(+)
997
1,547
D
Minus (-)
1,049
1,628
Normal
1,165
1,809
Plus(+)
1,282
1,990
H
IGH
- /S
INGLE
-S
TAGE
 & L
OW
-S
TAGE
 C
OOLING
 S
PEEDS
Notes:
•  These charts are for furnaces installed at 0 - 2000 feet. At higher altitudes, a properly derated unit will have the same temperature rise at a 
particular CFM, while the ESP at that CFM will be lower.
•  The installation must be adjusted to obtain a temperature rise within the range listed on the furnace nameplate.
•  Do not operate above .5” w.c. ESP in heating mode.
•  Propane gas installations will have a High Stage rise approximately 4° lower than shown in above table.
*   Motor CFM maximum
*   Motor CFM maximum
*   Motor CFM maximum