2.7.6 POWER 
SUPPLY CORD
The power supply cord must comply with all appli-
cable codes, standards and regulations. It must be 
large enough to handle the full amperage to which it 
will be subjected.
‹
2.7.7  GROUND FAULT CIRCUIT INTERRUPTERS
The National Electrical Code (NFPA 70, 551-7) 
requires that ground fault circuit interrupters (GFCIs) 
on all external and some internal electrical recepta-
cles be installed. Contact the manufacturer or dealer 
for recommendations.
‹
Section 2 – Installation
Recreational Vehicle Generator
Figure 2.18 – Transfer Switch Isolation Method
PRIMEPACT
RV Service Locator 1-800-333-1322 • www.guardiangenerators.com
Maintenance Schedule
Check engine oil level
Change oil  
Change oil filter
Clean & re-oil foam pre cleaner 
Clean air intake
Clean & reset spark plugs
Replace fuel filter
Inspect battery posts & cables
“Exercise” generator
Every 8 hours
or before use
Every 25 hours
or 3 months
Every 100 hours 
or once a year




Figure 2.19 – Installation With Isolation Receptacle
PRIMEPACT
RV Service Locator 1-800-333-1322 • www.guardiangenerators.com
Maintenance Schedule
Check engine oil level
Change oil  
Change oil filter
Clean & re-oil foam pre cleaner 
Clean air intake
Clean & reset spark plugs
Replace fuel filter
Inspect battery posts & cables
“Exercise” generator
Every 8 hours
or before use
Every 25 hours
or 3 months
Every 100 hours 
or once a year