Vulcan-Hart BVD36FP52(F,L)N-1 Manual De Usuario

Descargar
Página de 40
Page 10
19400-3-0406
Framing  dimension  "A"  includes  a  three  inch  clearance 
for standoffs on firebox. 
Framing and Finishing 
  1.  Choose unit location.
  2.  Frame in fireplace with a header across the top. It is important 
to allow for the finished face thickness when setting the depth 
of the frame. See Figures 9 & 11. 
  3.  Attach fireplace to framing using (4) adjustable nailing flanges. 
Preset depth to suit facing material (adjustable to 1/2", 5/8" or 
3/4" depths).
  4.  Use (8) 1/2" hex-head screws supplied in hardware package  
to screw through slotted holes in nailing flanges, then screw 
into pre-drilled holes on fireplace side. Measure from face 
of fireplace to face of the nailing flanges to determine final 
depth.
Vent Pipe Clearance
Note:  Maintain one inch (1") of clearance around vertical vent pipe.   
Follow the B-Vent system instructions for installation requirements 
and  clearances.  Failure  to  follow  the  B-Vent  manufacturer's 
instructions may cause improper draft and possible fire hazard.
Figure 10
B-
TO
COMBUSTIBLES
NAIL OR OTHER SUITABLE FASTENER
MOUNTING
BRACKETS
Install the Fresh Air Kit - BVA1
A fresh air kit is available as an optional feature with this appliance. 
The fresh air kit helps to decrease the amount of room air taken by 
utilizing outside air for combustion. It is strongly recommended 
that  it  be  installed.  Installation  of  the  fresh  air  kit  should  be 
performed at the framing stage of the fireplace installation.
The fresh air kit installs on the left side of the fireplace.
To  install  the  BVA1  fresh  air  kit,  refer  to  the  installation 
instructions provided with the kit.
Note:  The  outside  air  kit  can  terminate  at  any  level  with 
the  exception  that  it  must  terminate  at  least  1  ft  below  the 
vent termination cap. The fresh air kit inlet hood should be 
positioned at least 2 ft above the ground level, in a manner that 
will not allow snow, leaves, etc. to block the inlet.
WARNING:  Exhaust  products  of  gasoline  engines  are 
hazardous.  The  outside  air  must  not  be  taken  from  a 
garage space, attic spaces, basements, or above the roofing 
where other heating appliance, fans, or chimneys exhaust 
or utilize the air.
Figure 9
Framing (Figure 11)
Fireplace framing can be built before or after the fireplace is set in 
place. Framing should be positioned to accommodate wall covering 
and  fireplace  facing  material. The  fireplace  framing  should  be 
constructed of 2 x 4 lumber or heavier. The framing headers may 
rest on the fireplace standoffs. Refer to Figure 11 for minimum 
framing dimensions.
CAUTION: MEASURE FIREPLACE DIMENSIONS AND 
VERIFY FRAMING METHODS, AND WALL COVERING 
DETAILS  BEFORE  FRAMING  CONSTRUCTION 
BEGINS.
INSTALLATION