Empire Comfort Systems PV-28SV55-(C,G)2H(N,P)-1 Manual De Usuario

Descargar
Página de 56
24820-1-0409
Page 8
Model 
PV28SV50
Input BTU/HR (KW/H)
19,000 Rear - 9,000 Front
Height
25 1/8”
Width
28 3/16”
Depth
17 5/8”
Gas Inlet (Pipe)
3/8” Flair
Electrical -  Unit has a 5’ (1.5 m) 3 pronged cordset for con-
nection to an approved 115 VAC 60 Hz maximum 
AMPs - 5A wall receptacle.
Accessories
Part Number
Description
PV-2H
Top Cover - Slim Assembly
PV-4H
Top Cover - Short Assembly
PVPK
Pedestal Kit
PVE-1
6” Surround Assembly
PVSH
Rear Shroud
TRW
Wall Thermostat - Wireless Remote
FRBTC
Battery Operated Remote w/Thermostat
FRBTP
Battery Operated Remote w/Programmable Ther-
mostat
T24V
24 Volt Thermostat
TMV2
Two-Stage Thermostats
CIPFP-1
Floor Pad Kit
CIFPB-1C
Corner Floor Pad Kit
PVVK24H
Direct Vent 24” Vent Kit
PVVK48H
Direct Vent 48” Vent Kit
PVVK-SH
Single Flue Horizontal Vent Kit
PVVK-SV
Single Flue Vertical Vent Kit
PVVK-CFA
Flex Vent Kit
PVCT
Colinear Transition
PVVTC
Vertical Termination Cap - 1.5”
PVCA
Colinear Adapter
SPECIFICATIONS
INSTALLATION INSTRUCTIONS - GENERAL SAFETY INFORMATION
1.  This installation must conform with local codes or, in the ab-
sence of local codes with NFPA54.
2.  Provide adequate clearances around the product for servic-
ing and ensure there are no obstructions to the combustion 
air intake situated at the back of the heater. Refer to Page 15, 
Figures 7 through 10.
3.  The appliance must be installed on a flat, solid continuous 
surface (i.e. wood, metal, concrete). Please Note: Rough or 
uneven surfaces can cause vibration or humming in the heat-
er.
4.  The Mantis Power-Vent High-Effeciency Fireplace can be in-
stalled in a wide variety of ways and will fit nearly any room 
layout. It may be installed in a recessed position, framed out 
into the room, or across a corner. For installation options re-
fer to page 15.
5.  This appliance (Insert and Freestanding Models) needs to be 
installed in such a way that the heater can be removed at all 
times to service the heater exchanger and flue fan located in 
the rear section of the heater.
Note:  Under no circumstances should the appliance be in-
stalled  under  conditions  which  would  not  allow  for 
easy  removal  of  the  appliance  to  carry  out  routine 
inspection and service to the appliance, to do so will 
void the warranty.
Note:  On  Single  Wall  flue  pipe  installations  (imitation  zero 
clearance fireplace) a minimum of 2” (50.8 cm) clear-
ance must be provided at the rear of the heater to enable 
the heater to get sufficient combustion air to the air inlet 
located at the rear of heater. Refer to installation instruc-
tions on page 15, Figures 7 through 10.
Note:  Where a mantel surround is being used on insert installa-
tions and zero clearance fireplace installations, the com-
bustion air intake slot located in the top mantel surround 
must have no obstructions to allow combustion air to en-
ter through the slot to the combustion air inlet located at 
the back of the heater.