Gas Control & Thermal Well Removal From Water Heater 
Note: The Component Disassembly, Gas Control Removal, and Gas Control Assembly 
sections replace pages 24-30 in the Defender Atmospheric service manual, p/n 
238-44943-00. 
Step 1. 
Move the gas control power switch to the “OFF” 
position.
Step 2. 
Unplug the water heater and Accessory Module from the 
wall outlet. 
Step 3. 
Drain the water heater to a point below the gas control 
level.
Step 4. 
Turn off the gas supply to the water heater and disconnect 
the gas piping from the gas control. 
Step 4. 
Disconnect the pilot tube 
using a 7/16” wrench and the main burner 
feedline with a 3/4” wrench from the gas
control.
Step 5. 
Disconnect the wire harnesses and spark igniter/
flame sense wire from the gas control.
Step 6. 
Remove the gas control & thermal well by rotating 
the flats of the Thermal Well counter clockwise using a 1-5/16” 
wrench.
Component Disassembly 
Gas control power 
switch 
Pilot and main 
feedlines 
Spark igniter/flame 
sensor wire 
Gas control
Flats of thermal
well
Water heater power cord and 
Accessory Module transformer 
24