Polycom EX Manual De Usuario

Descargar
Página de 150
Integrators’ Reference Manual for ViewStation EX, ViewStation FX, and VS4000
38
www.polycom.com
Serial Interface Control Signals
If you need to customize your V.35/RS-449/RS-530 interface, use 
the signal information in Table 2-21 below in addition to the 
information provided by your network equipment vendor. 
Table 2-21.  Serial Interface Control Signals
Signal 
(Pin)
In/Out
Description
Configuration Option
ST 
(TC/TT)
OUT
Send Timing 
(clock)
Normal: falling edge sends data
Inverted: rising edge sends data
RT (RC)
IN
Receive 
Timing (clock)
Normal: rising edge receives 
data
Inverted: falling edge receives 
data
RTS 
(RTS)
OUT
Request To 
Send
Normal: high is logic 1
Inverted: low is logic 1
DCD 
(DCD)
IN
Data Carrier 
Detect
Normal: high is logic 1
Inverted: low is logic 1
Filter: allow DCD to drop for 60 
seconds before changing call 
state
CTS 
(CTS)
IN
Clear To Send
Normal: high is logic 1
Inverted: low is logic 1
DTR 
(DTR)
OUT
Data Terminal 
Ready
Normal: high is logic 1
Inverted: low is logic 1
On: signal remains high
a
 
a. If set to ON, inverted is not an option.
DSR 
(DSR)
IN
Data Set 
Ready
Normal: high is logic 1
Inverted: low is logic 1
Answer: Use DSR as a Ring-In 
indication
b
b. DSR is not used as a ring-in indication if it is set to ANSWER in 
the V.35 Advanced Setup screen.