Polycom EX Manual De Usuario

Descargar
Página de 150
Chapter 4 - Installing Videoconferencing Systems
© Polycom, Inc.
81
3.
Connect the network side of the Quad BRI network interface 
module to the NT-1 device or to the ISDN network, as 
appropriate.
Figure 4-4.  
Quad BRI Network Interface Module (Network Side)
4.
If you are using an NT-1 device, connect it to the ISDN network.
You are now ready to power on and configure the system.
Installing a PRI Network Interface Module
This section provides information about installing the PRI network 
interface module. This module is available for the ViewStation FX 
and VS4000.
For performance specifications, cable diagrams and pinouts, and 
other technical information, please refer to 
External Power Supply
If the PRI network interface module loses power, it creates an alarm 
condition that may result in the service provider disabling the line. 
The PRI network interface must be connected to the external 12-volt 
DC power supply so that it does not lose power when the system is 
powered off. Connect the external power supply to an 
uninterruptable power supply (UPS) if possible.
The external power supply is mandatory for installations in Europe 
and is strongly recommended where not mandatory.