SERVICE (cont.)
Timer
Location:
 
The timer is located on the timer bracket in the 
grinder base. The bracket can be removed by loosen-
ing the two 8-32 screws beneath the timer dial(s).
Test Procedure:
1. 
Disconnect the grinder from the power supply.
2. 
Check the voltage across terminals TL1 & TL2 
with a voltmeter when the “Off/On/Start switch 
is  placed  in  the  “START”  (right)  position  and 
released. Connect grinder to the power supply. 
The indication must be:
 
(a)  120 volts ac for  two wire 120 volt mod-
els.
 
(b)  240 volts ac for two wire 240 volt models.
3. 
Disconnect the grinder from the power supply.
 
If voltage is present as described, proceed to 
step 4.
 
If voltage is not present as described, refer to 
the Wiring Diagram and check the grinder wiring har-
ness.
4. 
Remove the white/orange and white/yellow wires 
from terminals TL3 & TL5.
5. 
Check for continuity across the white/orange and 
white/yellow wires when the  Off/On/Start switch 
is placed in the “START” (right) position.
 
If continuity is present as described, reconnect 
the white/orange wire to terminal TL3 and the white/
yellow wire to terminal TL5, and proceed to step 6.
 
If continuity is not present as described, refer 
to the Wiring Diagram and check the grinder wiring 
harness.
6. 
Check the voltage across terminals TL1 and TL4 
with a voltmeter when the Off/On/Start switch 
is  placed  in  the  “START”  (right)  position  and 
released. Connect grinder to the power supply. 
The indication must be:
 
(a)  120 volts ac for  two wire 120 volt mod-
els.
 
(b)  240 volts ac for two wire 240 volt models.
7. 
Disconnect the grinder from the power supply.
 
If voltage is present as described, the timer is 
operating properly.  Refer to the Adjustments section 
to vary the amount dispensed.
 
If voltage is not present as described, replace 
the timer.
Removal and Replacement:
1. 
Remove all wires from the timer terminals.
2. 
Remove the four 6-32 screws and nuts holding 
the circuit board to the timer bracket.
3. 
Remove the two 6-32 screws and nuts holding 
the dial plate to the timer bracket.
4. 
Install the new dial plate and circuit board to the 
timer bracket.
5. 
Refer to the illustration below when reconnecting 
the wires.
6. 
Refer  to  the  Adjustments  section  to  vary  the 
amount dispensed.
MIN
UTE
S
BUNN-
O-M
ATI
C
P/N 
262
0-   
120
 VA
C
MIN
UTE
S
BUN
N-O
-MA
TIC
P/N
 262
0-   
120
 VA
C
MINUTES
BUNN-O-MA
TIC
P/N 2620-   120
 VAC
2
3
4
5
WHI/RED to Relay N.O.
WHI/RED to  
Off/On/Start Switch
WHI to Cordset (120 v) 
RED/BLK to Cordset (240 v)
WHI/ORA to 
Off/On/Start Switch
WHI/GRN to Relay Coil
WHI/YEL to  
Off/On/Start Switch
P1312
P1313
Single set timer shown
Multi set timer (Urn/Carafe) connections are the same
Single set timer shown
Multi set timer (Urn/Carafe) similar