INSTALLATION INSTRUCTIONS
2
3 ELECTRICAL 
GROUNDING 
INSTRUCTIONS
This appliance must be grounded. This oven is equipped with 
a cord having a grounding wire with a grounding plug. It must 
be plugged into a wall receptacle that is properly installed and 
grounded in accordance with the National Electrical Code and 
local codes and ordinances. In the event of an electrical short 
circuit, grounding reduces risk of electric shock by providing 
an escape wire for the electric current.
WARNING - Improper use of the grounding plug can result in 
a risk of electric shock.
ELECTRICAL REQUIREMENTS
The oven is equipped with a 3-prong grounding plug. DO 
NOT UNDER ANY CIRCUMSTANCES CUT OR REMOVE 
THE GROUNDING PIN FROM THE PLUG.
DO NOT USE AN EXTENSION CORD. If the power supply 
cord is too short, have a qualifi ed electrician or serviceman 
install an outlet near the appliance.
The Power Supply Cord and plug must be connected to 
a separate 120 Volt AC, 60 Hz, 15 Amp, or more branch 
circuit, single grounded receptacle. The receptacle should 
be located inside the cabinet directly above the Microwave 
Oven mounting location as shown in Figure 2.
NOTE:
1. If you have any questions about the grounding or 
electrical instructions, consult a qualifi ed electrician or 
serviceperson.
2.  Neither Electrolux nor the dealer can accept any liability for 
damage to the oven or personal injury resulting from failure 
to observe the correct electrical connection procedures.
4  HOOD EXHAUST DUCT
When the hood is vented to the outside, a hood exhaust duct 
is required. All ductwork must be metal; absolutely do not use 
plastic duct. Check that all connections are made securely. 
Please read the following carefully: 
EXHAUST CONNECTION:
 The hood exhaust has been designed 
to connect to a standard 3 
1
/
4
" x 10" rectangular duct. If round 
duct is required, a rectangular-to-round adapter must be 
used.
REAR EXHAUST:
  If a rear or horizontal exhaust is to be used, 
care should be taken to align the exhaust with the space 
between the studs, or wall should be prepared at the time it 
is constructed by leaving enough space between wall studs 
to accommodate exhaust.
MAXIMUM DUCT LENGTH:
 For satisfactory air movement, the 
total duct length of 3 
1
/
4
" x 10" rectangular or 6" diameter round 
duct should not exceed 140 feet.
Elbows, adapters, wall caps, roof caps, etc. present additional 
resistance to air fl ow and are equivalent to a section of straight 
duct which is longer than their actual physical size. When 
calculating the total length, add the equivalent lengths of all 
transitions and adapters plus the length of all straight duct 
sections. Figure 3 shows the approximate feet of equivalent 
length of some typical ductwork parts. Use the values in 
parentheses for calculating air fl ow  resistance  equivalent, 
which should total less than 140 feet.
Opening for 
Power Cord
Figure 2
Ground 
Receptacle
Figure 3
45° Elbow (5 ft.)
Roof cap (24 ft.)
10" Wide Elbow (10 ft.)
Wall cap (40 ft.)
Adaptor (5 ft.)
90° Elbow (10 ft.)
90° Elbow (25 ft.)
45° Elbow (5 ft.)
ORM 1.8 [USA&Canada] [01EN].inddE2   E2
ORM 1.8 [USA&Canada] [01EN].inddE2   E2
1/22/09   10:22:43 AM
1/22/09   10:22:43 AM