Lexmark X644e Guía Del Usuario
PostScript
4-69
MaxSourceList
integer
(Read-only) See Table C-4 on page C-8 for the default value
of your printer.
of your printer.
MaxUPathCache
integer
Maximum bytes occupied by the user path cache.
Legal value: Any non-negative integer.
PageCount
integer
(Read-only) Total number of pages that have been printed.
PanelCode
1
string
(Read-only) Version of the operator panel code.
PrinterCode
1
string
(Read-only) Firmware version of the printer controller card.
PrinterName
string
Initialized from the printer name stored in NVRAM (the default
name of the printer). If this parameter is set to a zero length
string, the PrinterName is set to the value of the product
string in statusdict.
name of the printer). If this parameter is set to a zero length
string, the PrinterName is set to the value of the product
string in statusdict.
Legal value: Any string of 32 or fewer non-null characters.
RamSize
integer
(Read-only) Total amount of memory (in bytes) installed in the
printer.
printer.
RealFormat
string
(Read-only) Preferred representation for real numbers in
binary encoded tokens.
binary encoded tokens.
Revision
integer
(Read-only) The current revision level of the machine-
dependent portion of PostScript emulation.
dependent portion of PostScript emulation.
SearchBuiltinFontsFirst
1
boolean
Controls the device search order the interpreter uses to
locate fonts.
locate fonts.
SerialNumber
1
string
(Read-only) Serial number of your printer.
StartJob
string
(Write-only) Controls the ability of the startjob operator to
alter initial Virtual Memory (VM).
alter initial Virtual Memory (VM).
Legal value: Any integer or string of 32 or fewer non-null
characters. An integer is converted to a string.
characters. An integer is converted to a string.
StartupMode
integer
Controls the system start file (Sys/Start) during PostScript
emulation initialization. Also, controls the job start file (Job/
Start) before each print job.
emulation initialization. Also, controls the job start file (Job/
Start) before each print job.
0
Disable use of Sys/Start file and Job/Start file.
1
Sys/Start file executes (if present on disk or flash).
10
Job/Start file executes before each user job.
11
Both files run (a combination of 1 and 10).
Legal Values: 0 <= x <= 255. Values other than the four listed
are equivalent to 0.
are equivalent to 0.
Note: If both flash and disk have a Sys/Start file and Job/Start
file, the value of the SearchOrder for the two devices
determines which file is executed.
file, the value of the SearchOrder for the two devices
determines which file is executed.
StaticRamSize
1
integer
(Read-only) Amount of static memory (in bytes) on the
controller board.
controller board.
Table 4-10: PostScript Emulation System Parameters (Continued)
Key
Type
Definition
1
These parameters are Lexmark-specific and are in addition to the Adobe PostScript Language Supplement 2016.
2
These parameters are available with the Adobe PostScript Language Supplement 3010.
3