360436
WALL  BRACKET
REAR  VIEW
FRONT  VIEW
2 x 4
figure  1
figure  2
1
/
8
" MAX
This kit consists of the following:
1 Wall mounting bracket
2 Bottom Brackets
6-1/4 x 3 inch wood screws
7-1/4 x 1-1/2 inch wood screws
12 washers
Dryer Requirements
Carefully read and follow individual
dryer installation instructions for
exhausting requirements.
GENERAL INFORMATION:
The back of the dryer is not accessible for service or maintenance after dryer mounting installation is
complete. It is recommended that the dryer be checked and electrical installation completed prior to
mounting. For service or maintenance requiring rear access, the dryer must be removed from the wall.
CAUTION: DISCONNECT ELECTRICAL CURRENT BEFORE INSTALLING OR SERVICING DRYER.
The electrical outlet must be located above the dryer, or beside the dryer if adequate dryer-to-wall clearance
is available. The outlet must be within three feet on a 240 volt dryer or a 120 volt dryer from the service cord
entry on the rear of the dryer.
DRYER MOUNTING POSITION
These instructions explain two mounting positions for your 24 inch dryer.
INSTALLATION PROCEDURE:
1. Obtain two pieces of 2x4 long enough to span at least two wall studs and the width of the dryer.
2. Locate wall stud center lines. Mark wall stud center lines on two pieces of 2x4 in relationship to 
position dryer is to be mounted.
3. Referring to dimensional drawing, draw a horizontal reference line (78") from the floor to locate upper
2x4 support.
4. Position, level and secure upper 2x4 with four 1/4 x 3 inch wood screws. The bottom of the 2x4 should
be positioned on reference line.
5. Referring to dimensional drawing, draw a horizontal reference line 32" down from the bottom of the upper
2x4 support.
6. Position, level and secure lower 2x4 with two 1/4 x 3 inch wood screws. The center line of the 2x4
should be positioned on reference line.
7. Referring to figure 1, mount the metal wall bracket 1/8 inch from the bottom of the upper 2x4 support
with five 1-1/2 inch wood screws.
8. Referring to figure 2, remove one screw from each lower rear corner of dryer and, using same screws,
secure lower brackets (supplied) as shown.
9. Dryer is supplied with exhaust at the top, locate and install outside exhaust duct referring to the
dimensional drawing. For other optional exhaust directions as shown in dimensional drawing
(rear and sides) refer to dryer installation instruction sheet.
10. Position the dryer on the wall mounting bracket and check that the dryer is plumbed.
11. If the dryer needs plumbing, use some of the twelve washers supplied with the kit as spacers behind
lower brackets of figure 2 and secure the dryer to the lower 2x4 support using the remaining 1-1/2 inch
wood screws.
WMK-35 Wall Kit Installation
CAUTION
The 120 volt receptacle on the back of the 
240 volt dryer must not be used with this
wall mount kit.