Printronix l7032 Manual De Referencia

Descargar
Página de 416
Tab, Horizontal
 151
Specialized standard and expanded symbols are printable only in 
the horizontal orientation and are printed according to the size 
specification when the symbol was created. However, you can 
rotate the standard Registered Trademark symbol and Copyright 
Symbol when the Append Rotated configuration parameter is 
enabled. Refer to the VGL configuration parameters tables in 
your 
User's Manual.
Blank spacing occurs between plotted elements if an undefined 
number or character is assigned to a symbol in the Z command. 
Specialized symbols created with the z
x command remain in 
memory until the printer is reset or the printer power is turned off. 
Printing a specialized symbol after the data is lost causes VGL to 
react as if the symbol was created with null data, and blank 
spaces print in the place of the symbol.
Example
The following sample commands illustrate the standard symbols. 
Notice that the standard alphanumerics command was sent for 
symbol positioning.
^PY^-
^M02,02,000^DCopyright ^Z2 1986^-
^M03,03,000ACME MOTOR ^Z1 Inc.^-
^PN^-
Tab, Horizontal
Purpose
Specifies a new horizontal print position relative to the left page 
margin. 
Mode
Graphics with a Standard or an Extended Graphics Command 
selected
Format
(cc) T 
dis [(cc)-]
(cc)
Represents the Special Function Control Code 
(SFCC). Enter the specific SFCC for your VGL 
configuration.
T
The Horizontal Tab command. Enter T.
^T as a Standard Graphics command sets a 
"permanent" left Graphics margin for the start of all 
Extended Graphics command sequences. 
A ^T as an Extended Graphics command adds to 
this "permanent" margin.