Printronix P7000 Manual De Usuario

Descargar
Página de 338
78
Chapter
4
HOST INTERFACE
TOF Action
Reset (default). A form feed is performed before a warm start when the 
prime signal is asserted from the host. This setting is used only if the 
prime signal parameter is enabled. 
Do Nothing. Nothing occurs before a warm start when the prime signal is 
asserted from the host.
Buffer Size in K
Configures the amount of memory allocated for the Centronics parallel port 
buffer. You can specify between 1 and 16 Kbytes, in 1-Kbyte increments.
Auto Trickle
Auto Trickle is used to prevent a host computer from timing out because the 
parallel interface was busy for too long.  When Auto Trickle is enabled and the 
printer's buffers are almost full, the printer will begin to trickle data in (at the 
rate set in the Trickle Time menu) until the buffers start to empty out.
Trickle Time
When the printer is printing data from a host and a second job is received by 
the printer from a different host, Trickle Time prevents the second host from 
timing out while it is waiting for its data to be printed. In order to support this 
feature, the port has to be able to accept data from the host and store it for 
future use.
For example, if the printer is printing a job from the serial port, and then 
receives a second print job from the parallel port, the data from the parallel 
port will “trickle” bit by bit into the printer buffer to prevent a timeout error from 
being sent back to the host connected to the parallel port.
The selected value is the time that the printer waits before getting the next 
byte of data from the host. The Trickle Time value should be less than the 
host time out value, but not too much shorter or else the printer fills up its 
buffer too fast. This function is not applicable for C/T hotport.