APPENDIX A: Super DLTtape I Data Cartridge
SDLT 220 and SDLT 320 Product Manual
A-4
March 2004
81-85002-01
A dropped cartridge may have dislodged, loosened, or damaged internal 
components. If you drop a cartridge, give it a thorough visual inspection, as 
described in 
.
Never apply adhesive labels or “sticky” notes on the top, side, or bottom of 
your Super DLTtape I data cartridge. Only use the slide-in type label provided 
with each cartridge and slide it into the label slot on the cartridge.
Do not use graphite pencils, water-soluble felt pens, or other debris-producing 
writing instruments on your labels. Never erase a label — replace it.
Be certain you place the unused cartridge labels in the protective box so that 
you do not inadvertently pick them up along with the cartridge during 
subsequent usage. A static electricity charge on a cartridge may cause a label 
to cling to the cartridge. A label that is accidentally inserted into the drive 
along with a cartridge can prevent the hub reel and drive gear from meshing.
Follow all data cartridge handling instructions that accompany your cartridges 
or tape drive.
A.3 Data Cartridge Inspection Procedure
Ensure that your tape backup solution performs reliably by following the Visual 
Mechanical Inspection (VMI) procedures described in this subsection. These steps 
will help you identify any potential data cartridge problems, and will prevent 
accidental loss of data or damage to your SDLT system.
You should do an inspection:
As a general practice whenever you change or load a new data cartridge
If a data cartridge is dropped or subjected to some hard physical shock
If the SDLT drive becomes inoperable after loading a data cartridge
If you receive a shipment of data cartridges that show any sign of shipping 
damage.
Follow these steps to visually inspect a Super DLTtape I data cartridge:
1.
Remove the data cartridge from its protective plastic case.
2.
Check for loose debris attached to the shell, and for other contamination (oily, 
slimy, or sticky substances) that may have built up on the surface of the shell.