Champion pp-3 Manual De Usuario
C O N T R O L P A N E L S
Advanced Operation
Changing Temperature Set Point
Changing Temperature Set Point
The temperature set point is the water temperature setting for the wash tank and is the only
parameter that can be set by the operator. If the TEMP button is pressed once, the display
will switch back and forth from sp and 115 (115 represents the temperature setting and may
be different from your display).
parameter that can be set by the operator. If the TEMP button is pressed once, the display
will switch back and forth from sp and 115 (115 represents the temperature setting and may
be different from your display).
Use the UP or DOWN buttons to change the temperature setting. Once set, press the
TEMP button to lock in the new value.
TEMP button to lock in the new value.
NOTE:
If no key is pressed within three seconds, then your display will revert back to the way it was before
the TEMP button was pressed. If the temperature setting was changed and the TEMP button was not
pressed, then the temperature setting will remain unchanged.
pressed, then the temperature setting will remain unchanged.
Supervisor Mode
The supervisor mode can be accessed by holding the TEMP and START/STOP buttons
simultaneously for 3 seconds. The display will toggle opr and op.b. Pressing the UP or
DOWN buttons will toggle between “op.b”, “op.s”, “cpi.”, and “cnf.”.
simultaneously for 3 seconds. The display will toggle opr and op.b. Pressing the UP or
DOWN buttons will toggle between “op.b”, “op.s”, “cpi.”, and “cnf.”.
To exit the supervisor mode, press the UP or DOWN buttons until op.b
is displayed, then
press the TEMP button.
NOTE
: You may need to hold the TEMP and START/STOP buttons in
for 3 seconds to get to the menu.
Setup Mode –
ΟΠ.Σ
Enter the supervisor mode and press the UP or DOWN buttons until op.s
is displayed. Press
the TEMP button to select.
When prompted for a password (pss), use the UP and DOWN buttons to select 55. Press
the TEMP button to enter in the value.
the TEMP button to enter in the value.
Press the TEMP button to toggle between the parameters that are available, see parameter
table below.
table below.
The parameter name and its value will be swapped in and out of the display. Press the UP
and DOWN button to change the parameters value. Once a value has been changed, press
the TEMP key to lock in this value and move on to the next parameter. If you do not press
the TEMP key within three seconds after changing a parameters value, the new value will
not be saved.
and DOWN button to change the parameters value. Once a value has been changed, press
the TEMP key to lock in this value and move on to the next parameter. If you do not press
the TEMP key within three seconds after changing a parameters value, the new value will
not be saved.
Exit the supervisor mode when done with the setup mode.
NOTE:
See Supervisor Mode section
on how to exit.
15