Settings
 
When you have a MIDI sequencer connected, set this 
parameter to Local Off. Most conventional sequencers have 
the Thru function set to On, so as seen in the figure, when 
information describing what has been played on the keyboard 
(1) arrives at the sound generator via two separate routes (2), 
notes could be sounded twice or sometimes get cut off. To 
prevent this, the setting called “Local Off” is used to disconnect 
the route in (1).
 
Local On:
 
The keyboard and the internal sound generator are 
in a linked state.
 
Local Off:
 
The keyboard and the internal sound generator are 
in an unlinked state. No sound will be produced by 
the keyboard when it is played.
When a Roland MT series instrument is connected, it 
is not necessary to make the Local Off setting. The 
MT transmits a Local Off message when the power is 
turned on. If you turn on the power in the order of 
the VIMA 
 
 
 MT series, Local Off will be set 
automatically.
 
Disconnecting the Internal Sound 
Generator and Keyboard 
(Local Control)
(1)
MIDI
MIDI
MIDI
MIDI
(2)
IN
IN
OUT
OUT
Sequencer
Memory
Sound
Generator
Each note played is sounded twice
Soft Thru On
Local On
Local On
Sound is emitted
Sound Generator
Local Off
No sound produced
Sound Generator
 
Setting
Explanation
On
 
The Local Control is set to On.
The keyboard and internal sound generator are 
connected.
 
Off
 
The Local Control is set to Off.
The keyboard and internal sound generator are 
disconnected. Playing the keyboard will not 
produce sound.