Enterasys csx200 Guía Del Usuario

Descargar
Página de 261
Troubleshooting
204
CSX200 Family User’s Guide
Troubleshooting CSX200 Hardware
Power (PWR) LED is OFF
Check that the power connection is firmly attached to the back panel of the CSX200, and the 
other end to an active power source.
Processor (CPU) LED is OFF
If the CPU stays OFF for an extended amount of time, and the power (PWR) light remains on, the 
CPU is in an unknown state. 
).
Processor (CPU) LED is RED
The processor has detected a fault condition. 
Contact Cabletron Systems Technical Support (refer to 
Troubleshooting the LAN
Collision (CLN) LED is RED
Collisions are normal in an Ethernet network, however, increased collisions may indicate that the 
network is out of specification (the propagation delay between two nodes on the network exceeds 
25.6 
µ
s).
Link (LNK) LED is OFF
Check that the CSX200 and the device at the other end of the segment are powered up.
Verify that the RJ45 connectors on the twisted pair segment have the correct pinouts.
Check the cable for continuity.
Check that the cable meets the specifications for dB loss.