Enterasys 6000 Guía Del Usuario

Descargar
Página de 420
St atus and  Statistics Displays
17-25
LP/Port/Frame Statistics Displays
Displaying LP Statistics
Although an FRX4000 has no LPs, LP functionality exists in the device.
Figure 17-10    LP Statistics Display
[E],[B]
 from  Main Menu
Pressing 
[F2]
 on an FRX6000 display will show the next-higher-numbered 
LP in the specified node, or the lowest-numbered LP if the displayed LP is 
already the highest. Pressing 
[F4]
 will reset the 
MAX
 (maximum) values to 
the 
CURR 
(current) values.
Information in this Display
Percentage of buffers
is self-explanatory.
in use
Number of queued
is the total number of frames queued on the LP.
messages
Received frames
is the number of frames received on the LP per second over
per sec (*10)
the five-second reporting interval, multiplied by 10.
Transmitted frames
is the number of frames transmitted by the LP per second
per sec (*10)
over the five-second reporting interval, multiplied by 10.
Rejected frames
is the number of frames rejected by the LP per second over
per sec (*10)
the five-second reporting interval, multiplied by 10.
N ode Name= node_xyz
LP Statistics R ep ort
LP: 0
Report I nterval (s ec): 5
Start Time: 4/21/1997
09:41:49
CD STA TISTI CS NA ME
C URRMA X DA TE TI ME
A
Percen tage of Bu ffers in U se
75 80
4/21/199709:45:19
B
Nu mber of Queued Mes sages
5 9 
4/21/199709:45:19
C
Received frames/Sec (*10) 
230 238 
4/21/199709:45:19
D
Transmitted frames/Sec (*10) 
230 238 
4/21/199709:45:19
E
Rejected frames /S ec (*10)
0  8 
4/21/199709:45:19
F
Retransmitted Frames/Sec (*10)
0  2 
4/21/199709:45:19
F2:Next F4:C lear Max F9: Stop  R emote F10: Reboot  Remote Oth ers:Exit