MI B Ref erence
65
DESCRIPTION:Associated index into the MIB-II 
ifTable
 for this port.
::= { nlIfTable.1.4}
nlIfTableIndex
SYNTAX:
INTEGER
ACCESS:
Read only
STATUS:
Mandatory
DESCRIPTION:Index into a table used to describe additional information 
for this port. See
 nlIfTableOid
 as the pointer to the actual 
table.
::= {nlIfTable.1.5 }
nlIfTableOid
SYNTAX:
OBJECT IDENTIFIER
ACCESS:
Read only
STATUS:
Mandatory
DESCRIPTION:OID of the table entry that contains additional information 
about this port. The OID will point to a specific table 
depending on the type of port.
::= {nlIfTable.1.6 }
nlIfConnectorType
SYNTAX:
INTEGER {none (
2
), rs232 (
3
), v25bisDial (
4
), v35 (
5
), 
rs449 (
6
), rs530 (
7
), x21 (
8
), dsu/csu (
9
), t1 (
10
), e1 (
11
), 
voice 
(13
)
ACCESS:
Read only
STATUS:
Mandatory
DESCRIPTION:Physical connector type used for this port (valid for ports
 
1-8
 [actual port numbers 
0–7
] only)
.
::= { nlIfTable.1.7}
nlIfPortStatus
SYNTAX:
INTEGER (
1–13
)
ACCESS:
Read only
STATUS:
Mandatory
DESCRIPTION:Port state (valid for ports 
1–64 
[actual  port numbers 
0–63
only): 
1
 = Link up, 
2
 = Restarting, 
3
 = Operational,
 
4
 = Disabled,
 5
 = Disconnect, 
6
 = Configured, 
7
 = Dial 
ready, 
8
 = Quiesced,
 9
 = Failed, 
10
 = Hardware fault, 
11
 = Other, 
12
 = IPL, 
13
 = n/a, 
14
 = Remote loopback,