 7.1  Hot Swap Operating Instructions
To maintain array up time, individual disk drive sled assemblies, power supplies and blower assemblies can be 
replaced with the unit fully operational. Special instructions need to be followed to perform these operations.
Disk drives
The following cautions must be observed when hot 
swapping disk drives.
•  Individual disk drive sled assemblies may be 
replaced while the array is operating with no 
other intervention only if there is absolutely no 
activity
 on that drive. Failure to ensure no activity 
may destroy any data on that drive and possibly 
stop the entire array operation. Follow the 
instructions below using CLI commands to 
replace drives.
•  Removing a drive sled that is part of a RAID 
Level 0 group will result in the loss of all data in 
the groups associated with that sled. Follow 
your backup procedures when removing sleds.
•  Do not leave empty openings on the front or rear 
of the array under any circumstances. Empty 
openings affect airflow and may cause the unit 
to overheat and shut down.
•  All modular components must be replaced by 
qualified personnel only. Components are 
electrostatic sensitive. Use a static wriststrap 
when handling any of the cards inside the array. 
Use proper grounding methods. Always store 
spare components in proper ESD containers 
when not in use.
Follow your backup procedures before removing a 
sled. You may copy drives using the appropriate CLI 
commands (Refer to Drive Configuration Commands on 
page 45)
.
The following method is the safest way to perform a 
hot swap of a drive.
The general approach: identify the disk drive sled to be 
replaced, take it offline using the appropriate CLI 
commands, turn off its power using CLI commands, 
remove and replace with a new disk drive sled, power 
up the new sled, and place back on line.
1
Connect to Diamond Storage Array services 
(refer to 
on page 17) and 
enter the Command Line Interface mode. 
2
The fault LED should be blinking on the disk 
drive sled to be replaced. If it is not, type set 
SledFaultLED [n] on
. The LED of the drive 
you want [n] will light. 
3
Determine the Drive Sled Number. The disk 
drive sled closest to the management card is 
always the number 1 disk drive sled
The Drive Sled Number identified in step 2 is 
the SledNum variable to be entered into the 
CLI commands. Take the disk drive sled offline 
by entering the following CLI commands at the 
control computer Ready prompt
Set AtaDiskState (SledNum, 1, OFFLINE)
Set AtaDiskState (SledNum, 2, OFFLINE)
Set DriveSledPower (SledNum, OFF)
CAUTION
CAUTION
In a Hot Spare configuration, a drive sled should 
only be taken offline if there is absolutely no 
activity on that drive. If there is any activity, the 
rebuild of the Hot Spare sled may be flawed.
4
Wait 30 seconds for the disk drive sled to spin 
down and complete any remaining I/O activity.
5
Unscrew the two screws on the disk drive sled 
with the appropriate tool.
6
Carefully pull the disk drive sled out of chassis 
using its handle.
7
Mark or tag the disk drive sled with the array 
serial number, the date removed, and its slot 
number.
8
Place the disk drive sled in an appropriate ESD 
container or bag.
9
Install the replacement disk drive sled into the 
array chassis using proper ESD control steps 
and with the proper orientation (The disk drive 
sled assembly is keyed and can only be 
inserted one way).
10 Tighten the two screws on the disk drive sled 
with the appropriate tool.
11 If you do not have 
AutoRebuild enabled
, using 
the disk drive sled number identified in step 2, 
on the control computer Ready
 
prompt type