A. Configuration Options
A-10
 
 May 2002
7990-A2-GB20-00
Send All Ones on Data Port Not Ready
Possible Settings: Both, Disable, DTR, RTS
Default Setting: Both
Specifies the conditions on the data port that determine when valid data is not being sent 
from the DTE. When this condition is detected, all ones are sent to the network.
Both – Monitors both DTR and RTS. If either is interrupted, all ones are sent to the 
network.
Disable – Disables the monitoring of interchange circuits from the DTE connected to the 
synchronous data port.
DTR – Monitors the DTE Ready interchange circuit CD (CCITT 108/1/2). When DTR is 
interrupted, all ones are sent to the network.
RTS – Monitors the Request-to-Send interchange circuit CA (CCITT 105). When RTS is 
interrupted, all ones are sent to the network.
Action on Network LOS Alarm
Possible Settings: Halt, None
Default Setting: Halt
Specifies the action taken on the synchronous data port when an LOS (Loss Of Signal) 
alarm is received on the DSL interface.
Halt – Stops the transmission of data on the data port and disables the data port when an 
LOS alarm is received on the network interface. When LOS alarms are received, all ones 
are sent on the Received Data interchange circuit BB (CCITT 104). The Clear-to-Send 
interchange circuit CB (CCITT 106) is interrupted.
None – Makes the data port unaffected by LOS alarms received on the network interface.
Network Initiated Data Channel Loopback
Possible Settings: Disable, Enable
Default Setting: Disable
Allows the initiation and termination of a Data Channel Loopback (DCLB) by the receipt of 
a DCLB-actuate sequence or DCLB-release sequence from the network or far-end device.
Disable – Ignores the DCLB-actuate and DCLB-release sequences for this port.
Enable – DCLB-actuate and DCLB-release sequences are recognized for this port.
Table A-4.