Zhone 7995 Guía Del Usuario
6. Monitoring and Troubleshooting
7990-A2-GB20-00
May 2002
6-5
RAI (Remote Alarm
Indication) at G.703
Indication) at G.703
A Remote Alarm Indication
signal is being received by
the G.703 interface.
signal is being received by
the G.703 interface.
1. Verify that the units line
framing and line coding are
compatible.
compatible.
2. Contact network provider.
Remote Unit Power Off
The remote unit has lost
power (last gasp).
power (last gasp).
Contact network provider.
STU-R/STU-C
Mismatch
Mismatch
The STU-C and the STU-R
are incompatible units. For
example, the STU-C is a T1
device and the STU-R is an
E1 device.
are incompatible units. For
example, the STU-C is a T1
device and the STU-R is an
E1 device.
Contact network provider.
STU-R TS16 Not
Supported
Supported
The STU-C is configured for
TS16 signaling (Voice mode)
and the STU-R is not
configured to support TS16
signaling.
TS16 signaling (Voice mode)
and the STU-R is not
configured to support TS16
signaling.
1. Verify endpoint is a G.703
product. EIA-530-A products
do not support signaling.
do not support signaling.
2. Replace endpoint or
reconfigure TS16 to data.
System Operational
There are no problems
detected.
detected.
No action is needed.
Table 6-1.
Health and Status Messages (3 of 3)
Message
What Message Indicates
What To Do