ZyXEL 793H Guía Del Usuario

Descargar
Página de 444
Chapter 35 Menus 24.8 to 24.11
P-793H User’s Guide
340
Figure 234   Menu 24: System Maintenance
Enter 10 to go to Menu 24.10 - System Maintenance - Time and Date Setting to update the 
time and date settings of your ZyXEL Device as shown in the following screen.
Figure 235   Menu 24.10: System Maintenance - Time and Date Setting
The following table describes the fields in this screen.
                          Menu 24 - System Maintenance
                         1.  System Status
                         2.  System Information and Console Port Speed
                         3.  Log and Trace
                         4.  Diagnostic
                         5.  Backup Configuration
                         6.  Restore Configuration
                         7.  Upload Firmware
                         8.  Command Interpreter Mode
                         9.  Call Control
                         10. Time and Date Setting
                         11. Remote Management
             Menu 24.10 - System Maintenance - Time and Date Setting
          Time Protocol= None
          Time Server Address= N/A
          Current Time:                         06 : 43 : 17
          New Time (hh:mm:ss):                  06 : 43 : 00
          Current Date:                         2000 - 01 - 01
          New Date (yyyy-mm-dd):                2000 - 01 - 01
          Time Zone= (GMT+0100) Brussels, Copenhagen, Madrid, Paris
          Daylight Saving= No
      Start Date (mm-nth-week-hr):          Jan. - 1st  - Sun.(02)  - 00
      End Date (mm-nth-week-hr):            Jan. - 1st  - Sun.(02)  - 00
Table 128   Menu 24.10: System Maintenance - Time and Date Setting
FIELD
DESCRIPTION
Time Protocol
Enter the time service protocol that your timeserver uses. Not all time servers 
support all protocols, so you may have to check with your ISP/network 
administrator or use trial and error to find a protocol that works. The main 
differences between them are the format. 
Daytime (RFC 867) format is day/month/year/time zone of the server.
Time (RFC-868) format displays a 4-byte integer giving the total number of 
seconds since 1970/1/1 at 0:0:0.
The default, NTP (RFC-1305), is similar to Time (RFC-868).
Select None to enter the new time and new date manually.
Time Server 
Address
Enter the IP address or domain name of your timeserver. Check with your ISP/
network administrator if you are unsure of this information. The default is 
tick.stdtime.gov.tw