Here are the equations used to calculate the data presented in Figure 1:
The quiescent power draw is a maximum value and includes power drawn by the fan. The 
following equation converts power draw in watts to current draw in amperes:
The value used for Power Factor is 0.83. The Power Factor variable is needed to compen-
sate for the differnece in phase between the AC mains voltage and current. The following 
equation is used to calculate thermal dissipation:
The value used for inefficiency is 1.00-efficiency. The factor 3.415 converts watts to btu/
hr. Thermal dissipation in btu is divided by the constant 3.968 to get kcal. If you plan to 
measure output power under real-world conditions, the following equation may also be 
helpful:
AC Power Draw and Thermal Dissipation
The information provided on this page is calculated data based on driv-
ing both channels to rated output using the 1 kHz Maximum Average 
Power rating method.
Other parameters used in calculation include a conservative idle current 
estimate of 90 watts and a conservative estimate of effeciency at 65%.
Information is provided only for getting an idea of current draw and heat 
produced. Actual performance will vary depending on environment, pro-
gram material, load, signal, and AC mains voltage and frequency.
Values of calculated current draw are intended to represent average draw 
corresponding to the thermal breaker requriements that should be met to 
handle the amplifier as a load on the AC mains.
Peak current draw with dynamic program material may be significantly 
higher. Thermal information is provided to assist with calculating air 
conditioning needs. The data here should not be construed as specifica-
tions.
Duty cycle of various program material:
Individual speech: 10%
Acoustic/chamber music: 20%
Full-range rock music: 30%
Compressed rock music: 40%
Pink noise: 50%
Total measured output power
from all channels (watts)
Thermal
Dissipation
(btu/hr)
=
+
Quiescent Power
Draw (watts)
.35
x
Amplifier Efficiency (.65)
(
)
x 3.415
Current Draw
(amperes)
=
AC Mains Power
Draw (watts)
x
AC Mains
Voltage
Power
Factor (.83)
AC Mains Power
Draw (watts)
=
Total output power with all
channels driven (watts)
x Duty
Cycle
Amplifier Efficiency (.65)
+ Quiescent Power
Draw (watts)
Total output power with all
channels driven (watts)
Thermal
Dissipation
(btu/hr)
=
+
Quiescent Power
Draw (watts)
x Duty
Cycle
Amplifier Efficiency (.65)
(
)
x 3.415
.35
x
CE 2000
C E   S E R I ES 
A Harman International Company
Crown International, Inc.
1718 W. Mishawaka Rd.
Elkhart, IN 46517-9439
TEL: 574-294-8200
FAX: 574-294-8FAX
www.crownaudio.com
For more details refer to the applicable Operation 
Manual or contact Crown Factory Service. The 
provided data should not be construed as specif-
ciations.
Crown and Crown Audio® are registered trade-
marks of Cown international, Inc. Printed in 
U.S.A. 
©2005 Crown Audio, Inc.
04/05                                                 138367-1
LOAD
2 Ohm Stereo / 4 Ohm Bridge
4 Ohm Stereo / 8 Ohm Bridge
8 Ohm stereo / 16 Ohm Bridge
AC 
Mains 
Power 
Draw 
(watts)
Current Draw 
(Amps)
Thermal 
Dissipation
AC 
Mains 
Power 
Draw 
(watts)
Current Draw 
(Amps)
Thermal 
Dissipation
AC 
Mains 
Power 
Draw 
(watts)
Current Draw 
(Amps)
Thermal 
Dissipation
Duty
Cycle
120V
240V
btu/hr
kcal/hr
120V
240V
btu/hr
kcal/hr
120V
240V
btu/hr
kcal/hr
50%
1590
16.0
8.0
2100
529
1105
11.1
5.5
1521
383
705
7.1
3.5
1043
263
40%
1290
13.0
6.5
1742
439
902
9.1
4.5
1278
322
582
5.8
2.9
896
226
30%
990
9.9
5.0
1383
349
699
7.0
3.5
1036
261
459
4.6
2.3
749
189
20%
690
6.9
3.5
1025
258
496
5.0
2.5
793
200
336
3.4
1.7
602
152
10%
390
3.9
2.0
666
168
293
2.9
1.5
550
139
213
2.1
1.1
454
114
CE 2000