Operation Manual
CE Series Power Amplifiers
page 6
2.1 Unpack Your Amplifier
Please unpack and inspect your amplifier for 
any damage that may have occurred during 
transit. If damage is found, notify the transpor-
tation company immediately. Only you can ini-
tiate a claim for shipping damage. Crown will 
be happy to help as needed. Save the shipping 
carton as evidence of damage for the shipper’s 
inspection. 
We also recommend that you save all packing 
materials so you will have them if you ever 
need to transport the unit. Never ship the 
unit without the factory pack.
YOU WILL NEED (not supplied):
Input wiring cables 
Output wiring cables 
Rack and rack-mounting hardware for mount-
ing amplifier (or a stable surface for stacking)
WARNING: Before you start to set up 
your amplifier, make sure you read and 
observe the Important Safety Instruc-
tions found at the beginning of this
manual.
2.2 Install Your Amplifier
CAUTION: Before you begin, make sure 
your amplifier is disconnected from the 
power source, with power switch in the 
“off” position and all level controls 
turned completely down (counterclock-
wise).
Use a standard 19-inch (48.3 cm) equipment 
rack. See Figure 2.1 for amplifier dimensions. 
You may also stack amps without using a
cabinet.
NOTE: When transporting, amplifiers should be 
supported at both front and back.
2.3 Ensure Proper Cooling
When using an equipment rack, mount units 
directly on top of each other. Close any open 
spaces in rack with blank panels. DO NOT 
block front or rear air vents. The side walls of 
the rack should be a minimum of 2 inches (5.1 
cm) away from the amplifier sides, and the back 
of the rack should be a minimum of 4 inches 
(10.2 cm) from the amplifier back panel.
Figure 2.2 illustrates standard amplifier airflow.
2 Setup
Figure 2.1  CE 1000 and CE 2000 Dimensions
Figure 2.2  Airflow