Com-Tech 200/400/800/1600  Power Amplifiers
Fig. 6.2  Com-Tech 400 Minimum Power Matrix
Com-Tech 400 – 
Minimum Guaranteed Power (Watts)
Dual/Mono
Mode
Dual
(both channels
driven)
Bridge-Mono
(balanced output)
Parallel-Mono
FTC Continuous Average
At 0.1% THD
(See note 4)
1 kHz
20Hz-20kHz
200
205
205
405
405
415
225
215
215
440
430
435
415
425
440
Maximum Average
Load in Ohms
(Constant Voltage)
AC Mains
120 VAC, 60 Hz
1 kHz
At 0.1% THD
(See note 1)
At 0.1% THD
(See note 2)
240
220
225
475
450
455
440
440
455
20Hz-20kHz
215
210
215
425
425
435
Dual
(both channels
driven)
Bridge-Mono
(balanced output)
Parallel-Mono
200
200
210
380
405
415
225
215
220
430
430
440
420
435
440
240
220
225
465
435
455
450
445
455
215
205
220
415
410
435
At 0.05% THD
(See note 3)
1 kHz
235
220
225
465
440
450
430
440
450
235
215
225
455
435
450
445
445
450
100/120 VAC, 50/60 Hz
Dual
(both channels
driven)
Bridge-Mono
(balanced output)
Parallel-Mono
200
205
215
390
410
430
225
215
220
435
435
445
405
430
450
240
220
225
465
445
460
430
435
455
215
210
220
415
420
440
240
220
225
455
440
455
425
430
455
220/240 VAC, 50/60 Hz
25 (70V)
4
2
50 (140V)
8
12.5 (70V)
8
4
16
25 (70V)
4
2
50 (140V)
8
12.5 (70V)
8
4
16
25 (70V)
4
2
50 (140V)
8
12.5 (70V)
8
4
16