AC Power Draw and Thermal Dissipation:
Pink noise 12dB crest factor, bandwidth limited 22Hz to 22kHz.
Typical line impedance used.
Measurements made with 120VAC mains. Line current figures for 230VAC units derived by multiplying 120VAC figures by 0.5.
Data based on all channels driven.
watts in
watts out
dissapated
Btu/hr
kcal/hr
At Idle (sleep mode)
40
0
40
137
34
1/8th Power Pink Noise
8 Ohms/Ch.
1000x2
Typical of program material 
16 Ohms Bridge
2000
just at clip.
4 Ohms/Ch.
1000x2
8 Ohms Bridge
2000
2 Ohms/Ch.
1000x2
4 Ohms Bridge
2000
70/100V/Ch.
1000x2
140/200V Bridge 2000
1/3rd Power Pink Noise
8 Ohms/Ch.
1250x2
Typical of program material
16 Ohms Bridge
2500
with severe clipping.
4 Ohms/Ch.
1500x2
8 Ohms Bridge
3000
2 Ohms/Ch.
1500x2
4 Ohms Bridge
3000
70/100V/Ch.
1500x2
140/200V Bridge 3000
CTs 3000
Load
Rated 
Power
Line Current 
120VAC
Line Current 
230VAC
Watts 
Thermal Dissipation
7.2
3.6
579
313
266
907
229
8.5
4.2
697
381
316
1079
272
9.6
4.8
790
384
405
1384
349
7.2
3.6
579
313
266
907
229
13.7
6.8
1196
835
360
1230
310
16.2
8.1
1469
1010
459
1565
395
19.2
9.6
1686
1024
662
2259
570
13.7
6.8
1196
835
360
1230
310