Crown xls 202 Guia De Especificaciones

Descargar
Página de 2
Crown International
P.O. Box 1000
Elkhart, IN 46515-1000
TEL: 219-294-8200
FAX: 219-294-8FAX
www.crownaudio.com
08/01                                                            133616-1  
 
Crown’s Three-Year, No-Fault, Fully Transferable Warranty
Crown offers a Three-Year, No-Fault, Fully Transferable Warranty for every new Crown ampli-
fier—an unsurpassed industry standard. With this unprecedented No-Fault protection, your new 
Crown amplifier is warranted to meet or exceed original specifications for the first three years of 
ownership. During this time, if your amplifier fails, or does not perform to original specifications, 
it will be repaired or replaced at our expense. About the only things not covered by this warranty 
are those losses normally covered by insurance and those caused by intentional abuse. And the 
coverage is transferable, should you sell your amplifier.
See your authorized Crown dealer for full warranty disclosure and details. For customers outside 
of the USA, please contact your authorized Crown distributor for warranty information or call 
219-294-8200.
XLS 202
Specifications subject to change without prior notice. Latest 
information available at www.crownaudio.com.
Crown is a registered trademark of Crown International. Other 
trademarks are the property of their respective owners. Printed 
in U.S.A.
© 2001 Crown Audio, Inc.
Input/Output
Input Connectors: One per channel; back-
panel three-pin female XLR input connectors 
are provided.
Input Impedance (nominally balanced, nomi-
nally unbalanced): 20 k ohms, 10 k ohms.
Output Connectors: One pair of back-panel, 
5-way binding posts per channel; accepts 
banana plugs, spade lugs or bare wire. (Euro-
pean models do not accept banana plugs.)
DC Output Offset (shorted input): ±10 millivolts.
Output Signal: Stereo, unbalanced, two-
channel.
Protection
XLS Series amplifiers provide extensive pro-
tection and diagnostic capabilities, including 
built-in anti-clip limiters, switchable high-pass 
filters, output current limiting, DC protection, 
fuses, and special thermal protection for the 
unit’s transformers.
Construction
Ventilation: Flow-through ventilation from 
front to back.
Cooling: Internal heat sinks with forced-air 
cooling for rapid, uniform heat dissipation. 
Air Volume Requirements (per minute per 
unit): 80.15 ft³ (2.27 m³).
Dimensions: EIA Standard 19-inch (48.3-cm) 
rack mount width (EIA RS-310-B), 5.25-inch 
(13.3-cm) height and 12.6-inch (32.0-cm) 
depth behind the mounting surface.
Weight
Net Weight: 30 lbs. (13.0 kg).
Shipping Weight: 37 lbs. (17 kg).