15.2  Machine fault and operating problems  
Problem Probable 
Cause
Solution 
Green pilot lamp not lit 
when ON button pressed 
No incoming power 
Check connections at machine and power source. 
Lamp fuse or bulb is out 
Replace fuse/bulb. 
Motor will not turn 
Emergency Stop engaged 
Rotate Emergency Stop button to disengage. 
Electrical power supply 
Check: the phases; the cables; the plug; the socket. 
Also check that the motor connections are in place. 
Trigger switch not activating 
Check that socket/plug connection from handle to 
motor is inserted correctly; check micro-switch in 
trigger. 
Transformer 
Check that the voltages are present both on the input 
and output. Otherwise replace. 
Magnetic Contactor 
Check that the phases in it are present both on the 
input and output, that it is not jammed, that it closes 
when powered and that it is not causing short circuits. 
Change if any of these problems are found. 
Thermal relay 
Make sure it is closed, i.e. check that the phases are 
present in input and output,  that it is not causing short 
circuits and responds when the reset coil is closed. If it 
has tripped to protect the motor, check the amperage 
setting, re-set, and check the motor. Change if 
necessary. 
Motor 
Check that it has not burned out, that it turns freely 
and that there is no moisture in the connection 
terminal board box. The winding can be rewound or 
replaced by experienced motor repair personnel. 
 
Table 6 
 
 
 
 
  
 
 
 
 
16.0  Parts 
Ordering replacement parts 
Replacement parts are listed on the following pages. To order parts or reach our service department, call 1-
800-274-6848, Monday through Friday (see our website for business hours, www.waltermeier.com). Having the 
Model Number and Serial Number of your machine available when you call will allow us to serve you quickly 
and accurately.