KitchenAid KDRS505XSS Instruccion De Instalación

Descargar
Página de 40
16
2. Attach terminal lugs (located in the package containing 
literature) to line 1 (black), bare (green) ground, and line 2 (red) 
wires. Loosen (do not remove) the setscrew on the front of the 
terminal lug and insert exposed wire end through bottom of 
terminal lugs. Securely tighten setscrew to 
XX lbs-in. torque. See Bare Wire Torque Specifications chart.
Bare Wire Torque Specifications
Attaching terminal lugs to the terminal block - 20 lbs-in. (2.3 N-m)
3. Use 
³⁄₈" nut driver to connect the bare (green) ground terminal 
lug to the center terminal block post with one of the 10-32 hex 
nuts.
4. Connect line 1 (black) and line 2 (red) terminal lugs to the outer 
terminal block posts with 10-32 hex nuts.
5. Securely tighten hex nuts.
6. Replace terminal block access cover.
Make Gas Connection
Typical flexible connection
1. Apply pipe-joint compound made for use with LP gas to the 
smaller thread ends of the flexible connector adapters (see B 
and G in the following illustration). 
2. Attach one adapter to the gas pressure regulator and the other 
adapter to the gas shutoff valve. Tighten both adapters.
3. Use a 
¹⁵⁄₁₆" combination wrench and an adjustable wrench to 
attach the flexible connector to the adapters. Check that 
connector is not kinked.   
A. Terminal lug
B. Setscrew
C. Line 1 (black) wire
D. Bare (green) ground wire
E. Line 2 (red) wire
Wire Awg
Torque
8 gauge copper
25 lbs-in. (2.8 N-m)
6 gauge aluminum
35 lbs-in. (4.0 N-m)
A. 10-32 hex nut
B. Line 1 (black)
C. Ground-link screw
D. Bare (green) ground wire
E. Line 2 (red)
F. Terminal lug
A
B
C
D
E
B
F
A
E
D
C
A. Gas pressure regulator
B. Use pipe-joint compound.
C. Adapter (must have ½" male 
pipe thread)
D. Flexible connector
E. Manual gas shutoff valve
F. ½" or ¾" gas pipe
G. Use pipe-joint compound.
H. Adapter
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure 
gas pressure does not exceed 14" (36 cm) water 
column. 
Examples of a qualified person include: 
licensed heating personnel, 
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
A
B
C
D
E
F
G
H