KitchenAid KDRS505XSS Instruccion De Instalación

Descargar
Página de 40
20
To Convert Surface Burners
1. If installed, remove the burner grates.
2. Remove the burner caps.
3. Using a Phillips or T20 Torx
® 
screwdriver, remove the burner 
base. 
4. Apply masking tape to the end of a 
⁹⁄₃₂" (7.0 mm) nut driver to 
help hold the Natural gas orifice spud in the nut driver while 
changing it. Press nut driver down onto the Natural gas orifice 
spud and remove by turning it counterclockwise and lifting 
out. Set the Natural gas orifice spud aside. 
Use the following chart for correct LP gas orifice spud for each 
burner. Refer to the model/serial rating plate behind the control 
panel for proper sizing of LP gas orifice spuds for each burner 
location.
LP Gas Orifice Spud Chart
5. Replace the Natural gas orifice spud with the correct LP gas 
orifice spud. See the “LP Gas Orifice Spud Chart.”
6. Replace burner base and hand tighten the screws.
7. Replace burner cap.
8. Repeat steps 1 through 7 for the remaining burners.
9. Place Natural gas orifice spuds in plastic parts bag for future 
use and keep with literature package.
10. Replace burner grates.
11. Complete installation. See “Make Gas Connection” and 
Electronic Ignition System” sections.
Checking for proper cooktop burner flame is very important. 
The small inner cone should have a very distinct blue flame ¼" 
to ½" long. The outer cone is not as distinct as the inner cone. 
LP gas flames have a slightly yellow tip.
IMPORTANT: You may have to adjust the “LO” setting for 
each cooktop burner.
Natural Gas Conversion
1. Turn manual shutoff valve to the closed position.
2. Unplug range or disconnect power.
To Convert Gas Pressure Regulator
1. Locate gas pressure regulator at the rear of the range.
IMPORTANT: Do not remove the gas pressure regulator.
A. Burner cap
B. Gas tube opening
C. Burner base screws
D. Burner base
A. Natural gas orifice spud
Burner Rating
Color
Number 
4,000 BTU
Yellow
70L
7,000 BTU
Black
81L
9,100 BTU
Green
97L
14,000 BTU
Red
111L
A
B
C
D
A
A. To range
B. Shutoff valve (closed position)
C. Gas supply line
A. Gas pressure regulator
WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect anti-tip bracket to rear range foot.
Reconnect the anti-tip bracket, if the range is moved.
Failure to follow these instructions can result in death 
or serious burns to children and adults.
A
B
C
A