Electrical Requirements - Canada Only
If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrical installer determine that 
the ground path is adequate and wire gauge are in accordance 
with local codes.
Be sure that the electrical connection and wire size are adequate 
and in conformance with CSA Standard C22.1, Canadian 
Electrical Code, Part 1 - latest edition, and all local codes and 
ordinances.
A copy of the above code standards can be obtained from:
Canadian Standards Association
178 Rexdale Blvd.
Toronto, ON M9W 1R3 CANADA
Check with a qualified electrical installer if you are not sure the 
range is properly grounded.
*The NEC calculated load is less than the total connected load 
listed on the model/serial rating plate.
A time-delay fuse or circuit breaker is recommended.
This range is equipped with a CSA International Certified 
Power Cord intended to be plugged into a standard 14-50R 
wall receptacle. Be sure the wall receptacle is within reach of 
range’s final location.
Do not use an extension cord.
Gas Supply Requirements
Observe all governing codes and ordinances. 
IMPORTANT: This installation must conform with all local codes 
and ordinances. In the absence of local codes, installation must 
conform with American National Standard, National Fuel Gas 
Code ANSI Z223.1 - latest edition or CAN/CGA B149 - latest 
edition. 
IMPORTANT: Leak testing of the range must be conducted 
according to the manufacturer’s instructions.
Type of Gas 
Natural gas:
This range is design-certified by CSA International for use with 
Natural gas or, after proper conversion, for use with LP gas. 
This range is factory set for use with Natural gas. See “Gas 
Conversions” section. The model/serial rating plate located 
behind the control panel has information on the types of gas 
that can be used. If the types of gas listed do not include the 
type of gas available, check with the local gas supplier.
LP gas conversion:
Conversion must be done by a qualified service technician.
No attempt shall be made to convert the appliance from the gas 
specified on the model/serial rating plate for use with a different 
gas without consulting the serving gas supplier. See “Gas 
Conversions” section.
Gas Supply Line 
Provide a gas supply line of ¾" (1.9 cm) rigid pipe to the range 
location. A smaller size pipe on longer runs may result in 
insufficient gas supply. With LP gas, piping or tubing size can 
be ½" (1.3 cm) minimum. Usually, LP gas suppliers determine 
the size and materials used in the system.
NOTE: Pipe-joint compounds that resist the action of LP gas 
must be used. Do not use TEFLON
®†
 tape. 
WARNING
Electrical Shock Hazard
Electrically ground range.
Failure to do so can result in death, fire, or 
electrical shock.
Range Rating*
Rating of 
Power 
Supply 
Cord 
Circuit 
Protection
120/240 Volts
120/208 Volts
Amps
Amps
8.8 - 16.5 KW
16.6 - 22.5 
KW
7.8 - 12.5 KW
12.6 - 18.5 
KW
40
50
40 or 50
50
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure 
gas pressure does not exceed 14" (36 cm) water 
column. 
Examples of a qualified person include: 
licensed heating personnel, 
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
†®TEFLON  is a registered trademark of E.I. Du Pont De Nemours and Company.