Replacing the Lamp
 
Resetting the Lamp Timer
Reset the lamp timer after replacing the lamp. When the lamp has been replaced after the LAMP 
indicator is red, or the CHANGE THE LAMP message is displayed, complete the following 
operation within ten minutes of switching POWER ON. The POWER will be turned off 
automatically in about 10 minutes.
1
Switch POWER ON, and press the RESET button, for approximately three seconds. The “LAMP 
HOURS” message will display on the lamp timer on the bottom of the screen.
2
Press the MENU button on the remote control transmitter, or the RESET button on the control 
panel, while the lamp timer is displayed.
3
Press the
and select 0, and wait until the timer display is cleared.
Note: Do not reset the lamp timer without replacing the lamp. Reset the lamp timer always
when replacing 
the lamp. The message functions will not operate properly if the lamp timer is not reset correctly.
1
Switch the projector OFF, remove the power cord from the 
power outlet, and wait at least 45 minutes for the unit to 
cool.
2
Prepare a new lamp.
3
Check that the projector has cooled sufficiently, and gently 
turn it upside down.
4
Loosen the two screws as shown in the diagram, and remove 
the lamp cover.
5
Loosen the one screw, and gently remove the lamp while 
holding the grips. Touching the inside of the lamp case may 
result in uneven coloring.
6
Install the new lamp and tighten the one screw firmly. Make 
sure that the lamp assembly is seated properly before 
replacing the other screw.
7
Replace the lamp cover in position and tighten the two 
screws firmly.
8
Gently turn the projector right-side up.
    CAUTION
• Ensure that screws are tightened properly. Screws not tightened fully may 
result in injury or accidents.
• Do not use the projector with the lamp cover removed.
Figure 12: Lamp Replacement