Viewsonic PJ500 Guía Del Usuario

Descargar
Página de 31
21
ViewSonic  PJ500
2
 When the internal temperature rises too high, POWER to the unit switches OFF as a safety 
precaution; the LED lamp indicator turns OFF.  Set the POWER switch to [0] and wait 20 minutes 
until the equipment has cooled sufficiently before continuing with operation.
Symptom
Before requesting repair, refer to the chart below. If the problem cannot be corrected, contact your 
dealer.   
Blinks/Lights 
red
Lights red
Turns off
Lamp is not lit.
The interior of the equipment may be too hot. Switch POWER OFF, wait 
20 minutes until the equipment cools, and check whether the ventilation 
openings are blocked, whether the air filter is dirty, or whether the 
ambient temperature exceeds 95°F (35°C). And switch POWER ON 
again. 
Replace the lamp if the same problem occurs again.
Blinks/Lights 
red
Blinks red
Turns off
Lamp or lamp cover is not found, or hasn’t been fitted in correctly. Switch 
POWER OFF, and wait for 45 minutes until the equipment cools. Check 
fitting of the lamp and lamp cover, and switch POWER ON again. 
Contact your dealer if the same problem occurs again.
Blinks/Lights 
red
Turns off
Blinks red
The cooling fan is not operating.
Switch POWER OFF, and wait for 20 minutes until the equipment cools. 
Check for foreign matter in the fan, and switch POWER ON again. 
Contact your dealer if the same problem occurs again.
Blinks/Lights 
red
Turns off
Lights red
The interior of the equipment is too hot. 
2
Switch POWER OFF, and wait for 20 minutes until the equipment cools. 
Check whether the ventilation openings are blocked., whether the air 
filter is dirty, or whether the ambient temperature exceeds 95°F (35°C). 
Then switch POWER ON again. 
Contact your dealer if the same problem occurs again.
Lights green
Blinks red
Blinks red
The interior of the equipment is too cool. 
Check whether the ambient temperature is below 32°F (0°C). Contact 
your dealer if the same problem occurs when the ambient temperature is 
32°F  ~ 95°F (0°C ~ 35°C).
Table 11: Symptom 
Symptom
Possible cause
Remedy
Page
No power
The main POWER switch 
is not turned on.
Turn on the main POWER switch.
The power cord is 
disconnected.
Plug the power cord into an AC power outlet.
No video or 
audio
The Input is not correctly 
set.
Use the projector or remote control transmitter to set.
No signal input.
Connect correctly.
Video is 
present but 
no audio
The projector is not 
correctly connected.
Connect correctly.
The volume is set to 
minimum.
Press VOLUME
button on the remote control or display 
the menu screen and adjust the volume.
Mute is turned on.
Press the MUTE 
 button.
Table 10: Indicator Messages  (Continued)
POWER
indicator
LAMP
indicator
TEMP
indicator
Meaning or Action Required