GAS
Fixed piping installations
• Check with local gas utility
Fixed piping installations
• Check with local gas utility
company or with local codes
for instructions on installing gas
supply lines. All gas
connections should be made
by a competent technician and
in accordance with local codes
and or ordinances. In the
absence of codes, the
installation must comply with
the National Fuel Gas Code
ANSI Z223.1.
for instructions on installing gas
supply lines. All gas
connections should be made
by a competent technician and
in accordance with local codes
and or ordinances. In the
absence of codes, the
installation must comply with
the National Fuel Gas Code
ANSI Z223.1.
• An installer-supplied gas shut-
off valve must be installed in an
easily accessible location. All
installer-supplied parts must
conform to local codes.
easily accessible location. All
installer-supplied parts must
conform to local codes.
• Must be isolated from the gas
supply piping system by closing
its individual manual shut-off
valve during any pressure
testing of that system at test
pressures equal to or less than
1/2 psi (3.5 kPa).
its individual manual shut-off
valve during any pressure
testing of that system at test
pressures equal to or less than
1/2 psi (3.5 kPa).
Natural gas models
• Water column pressure
• Water column pressure
o Operating pressure—4.0”
WCP
o Supply pressure of 6” – 14”
WCP
o If incoming pressure exceeds
14” WCP, a step-down
regulator is required.
regulator is required.
• Accepts standard residential
1/2” (1.3 cm) ID gas service
line; 1/2” (1.3 cm) NPT male
with 7/8” (2.2 cm) flare adapter.
line; 1/2” (1.3 cm) NPT male
with 7/8” (2.2 cm) flare adapter.
o If using a Viking GSH12
flexible hose, remove the
1/2” (1.3 cm) flare adapter
and attach hose to the 7/8”
(2.2 cm) male flare on the
regulator assembly.
1/2” (1.3 cm) flare adapter
and attach hose to the 7/8”
(2.2 cm) male flare on the
regulator assembly.
LP/propane models
• Water column pressure
• Water column pressure
o Operating pressure—10”
WCP
o Supply pressure of 11” – 14”
WCP (for fixed piping
installations)
installations)
o If incoming pressure exceeds
14” WCP, a step-down
regulator is required.
regulator is required.
• Accepts standard residential
1/2” (1.3 cm) ID gas service
line; 1/2” (1.3 cm) NPT male
with 3/8” (0.95) flare adapter.
line; 1/2” (1.3 cm) NPT male
with 3/8” (0.95) flare adapter.
LP/propane tank installations
• Water column pressure
• Water column pressure
o Operating pressure—10”
WCP
• Includes high-capacity
hose/regulator assembly for
connection to a standard 5-
gal./20-lb. (approx. 12”
diameter/18”H.) LP/propane
gas cylinder equipped with a
Type 1, QCC-1 connector
o The cylinder connection
connection to a standard 5-
gal./20-lb. (approx. 12”
diameter/18”H.) LP/propane
gas cylinder equipped with a
Type 1, QCC-1 connector
o The cylinder connection
device must be compatible
with the Type 1, QCC-1
connector on the outdoor
cooking appliance.
with the Type 1, QCC-1
connector on the outdoor
cooking appliance.
o The cylinder must be
provided with a shut-off valve
terminating in an LP/propane
terminating in an LP/propane
gas supply cylinder valve
outlet specified.
outlet specified.
o The cylinder supply system
must be arranged for vapor
withdrawal and provided with
a listed OPD (overfilling
prevention device).
withdrawal and provided with
a listed OPD (overfilling
prevention device).
ELECTRICAL
• T-Series models
• T-Series models
o 9-volt DC battery for
electronic ignition (not
included?)
included?)
o 2’ (61.0 cm) power cord
supply cord with 3-prong
grounded plug attached to
rotisserie
grounded plug attached to
rotisserie
•
120 VAC/60 Hz
o Rotisserie motor max. amp
usage—6.0
• E-Series models
o 3’ (91.4 cm) power cord
supply cord with 3-prong
grounded plug attached to
grill
grounded plug attached to
grill
•
120 VAC/60 Hz
o Grill max. amp usage—3.0
o 2’ (61.0 cm) power cord
o 2’ (61.0 cm) power cord
supply cord with 3-prong
grounded plug attached to
rotisserie
grounded plug attached to
rotisserie
•
120 VAC/60 Hz
o Rotisserie motor max. amp
usage—6.0
PLUMBING
• Not applicable
• Not applicable
P L A N N I N G A N D D E S I G N G U I D E
V I K I N G R A N G E . C O M
•
1 - 8 8 8 - V I K I N G 1
OUTDOOR—COOKING
53”W. Ultra-Premium T-Series/E-Series Gas Grill
UTILITY
REQUIREMENTS
Installation Requirements
VGBQ530-4RE1
VGBQ532-3RE1
VGIQ530-4RT/E1
VGIQ532-3RT/E1
Burner rating
Standard SS grill burners (each)
25,000 BTU (7.3 kW) Nat./22,500 BTU (6.5 kW) LP (T-Series)
29,000 BTU (7.3 kW) Nat./28,000 BTU (6.5 kW) LP (E-Series)
Smoker burner (split standard)
12,500 BTU (3.7 kW) Nat./10,500 BTU (3.1 kW) LP
GourmetGlo™ rotisserie burner
15,000 BTU (4.4 kW) Nat./13,500 BTU (4.0 kW) LP
Side grill burners (each)
15,000 BTU (4.4 kW) Nat./
15,000 BTU (4.4 kW) Nat./
13,500 BTU (4.0 kW) LP
13,500 BTU (4.0 kW) LP
TruSear infrared burner
30,000 BTU (8.8 kW) Nat./LP
30,000 BTU (8.8 kW) Nat./LP