Viking Range detu200-4b Guia De Especificaciones
28-3/4”
(73.0 cm)
27”
(68.6 cm)
7/8”
(1.9 cm)
7/8”
(1.9 cm)
2-1/4”
(5.7 cm)
20-1/4”
(51.4 cm)
34”
(86.4 cm)
33”
(83.8 cm)
7/8”
(1.9 cm)
7/8”
(1.9 cm)
2-1/4”
(5.7 cm)
20-1/4”
(51.4 cm)
DETU200-4B
DETU260-5B
Cutout width (A)
28-3/4” (72.9 cm) min. to 29” (73.7 cm) max.
34” (86.4 cm) min. to 34-9/16” (87.8 cm) max.
Cutout height
3-1/8” (7.9 cm)
Cutout depth (B)
19-1/4” (49.0 cm) min. to 19-5/8” (49.8 cm) max.
Surface burner rating
240V
208V
240V
208V
240V
208V
Left front
1,800 watts 1,350 watts
Bridge
800 watts 600 watts
Left rear
1,800 watts
1,350 watts
Center
1,500 watts
1,125 watts
2,500/1,600/800 watts
2,500/1,600/800 watts
Right front
N/A
N/A
1,500 watts
1,125 watts
Right rear
2,500/1,600/800 watts
1,875/1,200/600 watts
2,100 watts
1,575 watts
COOKING
Touch Control Electric 30”/36”W. Cooktop
P L A N N I N G A N D D E S I G N G U I D E
V I K I N G R A N G E . C O M • 1 - 8 8 8 - V I K I N G 1
R E L E A S E D 0 2 / 0 5 / 1 0
© 2 0 1 0 V R C — I N F O R M AT I O N S U B J E C T T O C H A N G E
UTILITY
REQUIREMENTS
GAS
Not applicable
Not applicable
ELECTRICAL
• 3-wire, 240-208/
• 3-wire, 240-208/
120VAC/60Hz; Unit
is equipped with
No. 10 ground wire
in conduit. Should be
fused separately.
is equipped with
No. 10 ground wire
in conduit. Should be
fused separately.
• Maximum amp
usage—
o DETU200-4B
o DETU200-4B
• 240V—35.0
• 208V—30.3
• 208V—30.3
o DETU260-5B
• 240V—45.0
• 208V—40.0
• 208V—40.0
PLUMBING
Not applicable
Not applicable
Installation Requirements
ACCESS REQUIREMENTS
DETU200-4B
30”W. Five-Element Cooktop
DETU260-5B
36”W. Five-Element Cooktop
30”W. Cutout*
36”W. Cutout*
B
A
Note: Based on a 24” deep cabinet with 3/4” backsplash.