16
Delfield
®
STANDARD LABOR gUIDELINES TO REPAIR OR REPLACE PARTS ON DELFIELD EqUIPMENT
Advice and recommendations given by Delfield Service Technicians do not constitute or guarantee any special coverage.
• A maximum of 1-hour is allowed to diagnose a defective component.
• A maximum of 1-hour is allowed for retrieval of parts not in stock.
• A maximum travel distance of 100 miles round trip and 2-hours will be reimbursed. 
• Overtime, installation/start-up, normal control adjustments, general maintenance, glass breakage, freight damage, and/or
correcting and end-user installation error will not be reimbursed under warranty unless pre-approved with a Service Work 
Authorization
 from Delfield.  You must submit the number with the service claim.
LABOR OF 1-HOUR IS ALLOWED TO REPLACE:
• Thermostat
•  Door Jamb Switch
• Evaporator/Condenser Fan Motor and Blade
•  Solenoid Coil
• Hi-limit/Thermal Protector Switch
•  Fan Delay/Defrost Termination Switch
• Compressor Start Components and Overload Protector
•  Door Hinges, Locks, and Gaskets
• Condensate Element
•  Thermometer
LABOR OF 2 HOURS TO REPLACE:
• Defrost Element
•  Solenoid Valve
• Locate/Repair Leak
LABOR OF 3 HOURS TO REPLACE:
• Condenser or Evaporator Coil
• Expansion Valve
LABOR OF 4 HOURS TO REPLACE
• Compressor
This includes recovery of refrigerant and leak check.
$35.00 maximum reimbursement for refrigerant recovery (includes recovery machine, pump, torch, oil, flux, minor fittings, 
solder, brazing rod, nitrogen, or similar fees.)
REFRIgERANTS
• R404A A maximum of $15.00/lb. or ??¢/oz. will be reimbursed.