5. Reliability Test Items 
(Note3) 
Item 
Test Conditions 
Remark 
High Temperature Storage 
Ta = 85℃                                240 hrs 
Note 1,Note 4 
Low Temperature Storage 
Ta = -30℃                              240hrs 
Note 1,Note 4 
High Temperature Operation 
Ts = 85℃                                240hrs 
Note 2,Note 4   
Low Temperature Operation 
Ta =-30℃                                240hrs 
Note 1,Note 4 
Operate at High Temperature 
and Humidity 
+60℃, 90%RH max.            240 hrs 
Note 4 
Thermal Shock 
-30℃/30 min ~ +85℃/30 min for a total 100 
cycles, Start with cold temperature and end 
with high temperature 
Note 4 
Vibration Test   
Frequency range:10~55Hz 
Stroke:1.5mm 
Sweep:10Hz~55Hz~10Hz 
2 hours for each direction of X. Y. Z. 
(6 hours for total) 
 
Mechanical Shock 
100G 6ms,±X, ±Y, ±Z 3 times for each 
direction 
 
Package Vibration Test 
Random Vibration : 
0.015G*G/Hz from 5-200HZ, -6dB/Octave 
from 200-500HZ 
2 hours for each direction of X. Y. Z. 
(6 hours for total) 
 
Package Drop Test 
Height:60 cm 
1 corner, 3 edges, 6 surfaces 
 
Electro Static Discharge 
± 2KV,    Human Body Mode, 100pF/1500Ω 
 
    Note 1: Ta is the ambient temperature of samples. 
Note 2: Ts is the temperature of panel’s surface. 
            Note 3: In the standard condition, there shall be no practical problem that may affect the 
display function. After the reliability test, the product only guarantees operation, 
but doesn’t guarantee all the cosmetic specification. 
Note 4: Before cosmetic and function test, the product must have enough recovery time, 
                          at least 2 hours at room temperature.