B. 
WHEN VENT PIPE EXTENDS TO CHIMNEY TOP 
        (Refer to Figures 16 and 17) 
 
1. 
You will need a pipe length equal to the chimney height 
(from hearth) plus 6 inches. If outside combustion air is to 
be used, you will need a pipe length (see “COMBUSTION 
AIR SUPPLY”
) equal to the chimney height plus 12 
inches. 
 
2. 
Attach cerablanket wrap to that end of vent pipe that will 
connect to the stove. Use 12-inch lengths of light gauge 
metal wire (not included) or metallic tape (not included). 
This is to protect interior components from excess heat. 
 
3. 
Set the insert on the hearth and slide it in far enough to 
attach the vent pipe (and combustion pipe if used). 
 
4. 
Attach flashing (refer to Figure 15), route power cord out 
the side nearest a 120V receptacle. Slide in insert. 
 
5. 
Measure and build chimney top. Cut out hole for vent pipe 
(and combustion air intake pipe, if used). Install and seal 
with a non-hardening mastic to prevent water leakage. 
Install the vent cap. 
 
C. 
WHEN VENT PIPE EXTENDS THROUGH CHIMNEY 
BLANKING PLATE 
        (Masonry Fireplaces Only) 
        (Refer to Figures 16 and 17) 
 
1. 
You will need a pipe length that extends 12” above the 
blanking plate. NOTE: This installation is optional but not 
recommended. Outside combustion air cannot be drawn 
from the chimney cavity in this installation. 
 
2. 
Attach cerablanket wrap to that end of vent pipe that will 
connect to the stove. Use 12-inch lengths of light gauge 
metal wire (not included) or metallic tape. This is to protect 
interior components from excess heat. 
 
3. 
Measure and build blanking plate. Cut out hole for vent 
pipe (and combustion air intake pipe, if used). Install and 
carefully seal blanking plate with non-hardening mastic. 
Failure to properly seal may result in smoke spillage. 
 
4. 
Slide vent pipe (and intake pipe if used) up through the 
blanking plate hole, leaving enough to pull back down. 
 
5. 
Set the insert on the hearth, adjust the leveling bolts on 
the rear sides, and slide it in far enough to attach the vent 
pipe (and combustion air pipe if used). Be sure to seal 
where the pipe passes through the blanking plate. 
 
6. 
Attach flashing (refer to Figure 15), route power cord out 
the side nearest a 120V receptacle. Slide in insert. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
FIGURE 16 
INSTALLATION 
12 
FIGURE 17