     Do  not  damage   any   parts  of  the air conditioner
that carry refrigerant by piercing or perforating the
air conditioner's tubes with sharp or pointed items,
crushing or twisting off the surfaces. If  the  refrigerant
spurts out and gets into eyes, it may result in serious
eye  injures.
     Always remember to unplug the air conditioner before
openning inlet grill. Never unplug your air conditioner
by pulling on the power cord. Always grip plug firmly
and pull straight out from the outlet.
       All electrical repairs must be carried out by qualified
electricians. Inadequate repairs may result in a major
source of danger for the user of the air conditioner.
Cooling
Heating
Indoor
outdoor
Rated Maximum Minimum
  27          32               18
  19          23               14
  35          43               -5
  24          26                --
  20          27               15
 14.5         --                 --
   7           24               -15
   6           18                 --
Indoor
outdoor
DB  C
WB  C
DB  C
WB  C
DB  C
WB  C
DB  C
WB  C
Cautions
Disposal of the old air conditioner
Before disposing an old air conditioner that  goes out
 of use,  please  make sure
it's inoperative and safe. Unplug the air conditioner
in order to avoid the risk of child entrapment.
It must be noticed that air conditioner system contains
refrigerants, which require specialized waste disposal.
The valuable materials contained in a air conditioner
 can  be  recycled.   Contact
your local waste disposal center for proper disposal
of an old air conditioner and contact your local
authority or your dealer if you have any question.
Please ensure that the pipework of your air
conditioner  does  not  get damaged  prior
to being picked up by the relevant waste disposal
center, and contribute to environmental  awareness
by  insisting
on an appropriate, antipollution method of disposal.
Disposal of the packaging of your
new air conditioner
Safety Instructions and Warnings
Before starting the air conditioner, read the information
given in the User's Guide carefully. The User's Guide
contains very important observations relating to the
assembly ,  operation   and  maintenance  of
the air conditioner.
The manufacturer does not accept responsibility for any
damages that may
arise due to non-observation of the following instruction.
     Damaged air conditioners are not to be put into
operation. In case of doubt, consult your supplier.
All the packaging materials employed in the package
of your new air conditioner may be disposed without
any danger to the environment.
The cardboard box may be broken or cut into smaller
pieces and given to a waste paper disposal service.
The wrapping bag made of polyethylene and the
polyethylene foam pads contain no fluorochloric
hydrocarbon.
All  these  valuable  materials  may be taken
to a waste collecting center and used again after adequate
recycling.
Consult   your  local authorities for the name
and   address   of   the   waste    materials
collecting centers and waste paper disposal services nearest
to your house.
       Use of the air conditioner is to be carried out in strict
compliance with the relative instructions set forth in the
User's Guide.
     Installation shall be done by professional people, don't
install unit by yourself.
     For the purpose of the safety, the air conditioner must
 be properly grounded in  accordance with specifications.
      Do not allow children to play with the air  conditioner.
In no case should children be allowed to sit on the outdoor
unit.
     Do not obstruct or cover the ventilation grille of the  air
conditioner. Do not put fingers or any other things    into the
inlet/outlet and swing louver.
Specifications
1) The refrigerating circuit is leak-proof.
2) Please keep the air-conditioner  under conditions
in the following table during operation to ensure
proper use of it.
3)The wiring diagram refer to the wiring diagram on the
indoor and ortdoor units.
4)  If the fuse on electrical heater is broken please
       change it with the type of AC 250V 15A.
      If the fuse on main circuit is broken please change
       it with the same type ofAC 250V 5A
5)For AS072 ~ 182FABHA the indoor unit installation
height is at least 2.0m.