Newco moo-cafe Guía Del Usuario

Descargar
Página de 36
 
6
 
Machine Set-Up
 
 
 
NOTE: The MCM-Combo machine weighs approximately 100 LBS .  Use more than 
one person when unpacking and lifting machine.  DO NOT LIFT BY THE DOOR. 
 
See illustrated machine set-up guide supplied with equipment. 
 
1. 
Remove the box containing the accessories listed above.  Open and 
remove the 4” plastic legs and the drain pan, drain pan housing (black), 
and the drain pan support with hose.
 
Once equipment is out of the box, 
install the 4” plastic legs to the base of the machine.  Note: The front legs 
and drain support bracket must be installed at the same time.
  Align 
bracket holes with the holes in the front of the machine base, and secure 
by screwing the plastic legs tightly against bracket.  The 4” legs are 
designed to hold the drain support bracket to the base of the machine.  The 
drain bracket has an 6’ drain hose attached for hookup.  Place equipment 
at final location and plumb in the drain line.  Note: The equipment must be 
plumbed to a drain because of the Automatic Sanitation System Feature of 
the machine. 
2.  Install the two (2) florescent bulbs in the door face and rotate ¼ turn to seat 
in socket.  Unscrew and remove the three (3) brass screws in the inside top 
of the door panel and remove door cap.  Remove the translucent durotrans 
sign from the protective cardboard sleeve, remove protective film from 
both sides of sign, and install by sliding the sign panel from the top of the 
door opening down following the slide guides until the sign is seated at the 
bottom of the guides.  Re-seat door cap and secure with the three (3) brass 
screws. 
3.  This equipment is shipped with a water filter.  Before installation unscrew 
the blue top ass’y, remove the filter cartridge and remove the ‘plastic wrap’.  
Re-assemble and follow the ass’y instructions provided with the filter. 
Install the water filter bracket (use 2 #8 screws) on either side of water line 
connection, upper rear center of machine, and install water filter & 
connections to the to the water inlet outlet located in upper rear of  
Machine. Note: Pre-flush filterand water lines  before connecting to 
equipment water inlet.
 
4.  Connect free end of plain water lines to water supply. Note: This equipment 
is to be installed to comply with the applicable Federal, State, or local 
plumbing codes having jurisdiction.  Flow requirements: Minimum flowing 
pressure of 35 PSIG (2.46 kg/cm 2, 2.41 BAR) Maximum static pressure of 
100 PSIG (7.02 kg/cm 2, 6.85 BAR
) Provide enough extra coiled tubing (at 
least 2x the depth of the unit) so that the machine can be moved for 
cleaning underneath. 
5.  Turn on water supply and check for leaks.