6000 System Administrator’s Guide
 
98
 
 
 
 
Figure 53:  RVP_Direct Call_Suspend Settings 
3. Press 
the 
Èand Ækey to the Timeout parameter. This parameter causes the units to go into 
Call Suspend mode when no activity occurs for the set Timeout value. Set the value between 
15 and 240 minutes. 
4. Press 
the 
È
 and Ækey to the Minimum Connect Time parameter. Enter a value, in minutes 
(0 –240) that the EXTender will be connected to the Gateway before falling into Call 
Suspend.  
5. Press 
the 
È
 and Ækey to the Remote Only Wakeup parameter. If you set this parameter to 
Yes, you enable wakeup from Call Suspend on activity at the Branch site only (for example, 
when a telephone set goes off-hook or a key is pressed). If you set this parameter to No 
(disabled), incoming calls can also cause wakeup from Call Suspend. 
6. Press 
the 
È and Ækey to the Remote Login Timeout parameter. Enter a value, in minutes 
(15 – 240) that the EXTender will be in idle, before Call Suspend is enabled. 
7. Press 
the 
Åkey to accept changes and go back to the Configuration Menu. 
8.  Access the Call Suspend Menu on the Gateway. Set the Num Dials On Reboot, this is the 
number of times the Gateway will dial the Remote on a reboot, while in Call Suspend. 
 
Path: 
Gateway ->Configuration->Connect->RVP_Direct->Call_Suspend  
 
Figure 54:  Num Dials on Reboot