Citel 6000 Guía Del Usuario
PBXgateway
™
& EXTender
TM
6000 System Administrator’s Guide
98
Figure 53: RVP_Direct Call_Suspend Settings
3. Press
the
Èand Ækey to the Timeout parameter. This parameter causes the units to go into
Call Suspend mode when no activity occurs for the set Timeout value. Set the value between
15 and 240 minutes.
15 and 240 minutes.
4. Press
the
È
and Ækey to the Minimum Connect Time parameter. Enter a value, in minutes
(0 –240) that the EXTender will be connected to the Gateway before falling into Call
Suspend.
Suspend.
5. Press
the
È
and Ækey to the Remote Only Wakeup parameter. If you set this parameter to
Yes, you enable wakeup from Call Suspend on activity at the Branch site only (for example,
when a telephone set goes off-hook or a key is pressed). If you set this parameter to No
(disabled), incoming calls can also cause wakeup from Call Suspend.
when a telephone set goes off-hook or a key is pressed). If you set this parameter to No
(disabled), incoming calls can also cause wakeup from Call Suspend.
6. Press
the
È and Ækey to the Remote Login Timeout parameter. Enter a value, in minutes
(15 – 240) that the EXTender will be in idle, before Call Suspend is enabled.
7. Press
the
Åkey to accept changes and go back to the Configuration Menu.
8. Access the Call Suspend Menu on the Gateway. Set the Num Dials On Reboot, this is the
number of times the Gateway will dial the Remote on a reboot, while in Call Suspend.
Path: Gateway ->Configuration->Connect->RVP_Direct->Call_Suspend
Path: Gateway ->Configuration->Connect->RVP_Direct->Call_Suspend
Figure 54: Num Dials on Reboot