Troubleshooting
Vacuum cleaner won’t run
Possible Causes
Remedies
Vacuum cleaner is not plugged in
Check electrical plug
Household fuse/breaker
Check/replace fuse - 
Reset breaker button 
Motor Guard activated
Move Power Switch to OFF. Disconnect
plug from outlet. Remove Brush Cover
(See page 9). Remove visible obstructions.
Replace Brush Cover. Allow motor to cool 
for 5 minutes. Press Motor Guard button
to reset. 
Vacuum cleaner won’t pick up dirt
Possible Causes
Remedies
Dust Bag is full
Replace with new bag
Rotating Brush Drive Belt broken
Replace Drive Belt (See page 9)
Drive Belt stretched
Reposition belt/clean brush/belt areas
off Motor Pulley Shaft
(See page 9)
If Belt is stretched, it should be replaced
(See page 9)
Rotating Floor Brush bristles worn
Replace brush (See page 9)
Rotating Floor Brush jammed
Remove brush and clean debris from 
brush ends (See page 9)
Height adjustment too high
Reset Height Adjustment
Air Passageway clogged
Remove Brush Cover. (See page 9)
Clean debris from passageway
If still clogged: Remove Vacuum Body 
from Powerfoot.
Directions: 1. Remove screw from front 
of Vacuum Body (reverse of step 3. in How 
To Use section.)
2. Gently insert blade of flathead screwdriver
underneath the plastic tab on the back of the 
Vacuum Body to lift past the raised area 
inside the rectangular opening.
3. Pull upward on Vacuum Body handle 
and lift Vacuum Body off of Powerfoot.
Remove blockage.
Tools won’t pick up dirt
Possible Causes
Remedies
Vacuum Flex Hose clogged
Visually check for objects blocking
suction path and remove carefully
Full bag indicator light glowing
Possible Causes
Remedies
Dust Bag is too full
Replace with new bag
Vacuum path is blocked
Visually check hose and tools for 
obstruction. Remove Brush Cover and 
clean debris from passageway
suction path and remove carefully
Vacuum cleaner is difficult to push
Possible Causes
Remedies
Incorrect Height setting
Dial Adjustment to next highest setting
WARNING: 
To
reduce the risk of injury
from moving parts and/
or electrical shock, turn
Power Switch OFF and
disconnect polarized plug
from electrical outlet
b e f o r e   p e r f o r m i n g  
troubleshooting checks.