Section 700 - Operation
Chapter 3. System Features
576-50-700
DBS 576 (USA) issued September 2001
3-57
Accounting Code (10 digits max.)/Verified Account Code (Verified Account Code table number 
V001 to V500)
DISA Security Code ID (DISA ID Code table number D001-D016)
Caller Data (
Formats 
#2 
and #3
 only) 
(Format #2: Max 12 digits, Format #3: Max 16 digits)
ISDN Charge Data (Format #2 only - originator number applies to ISDN only) - Not used (Format # 2 
only) Future Use
Incoming Ringing Time (
Formats 
#2 
and #3
 only) (MM=00 to 59 / SS=00 to 59)
ISDN B-channel number (Format #3 only) (bb = None (space) or 01 to 30)
Carriage Return Line Feed
Related Programming
FF2: SMDR for Outbound Calls (for Analog, E&M Tie Line, and ISDN)
FF2: SMDR for Inbound Calls (for Analog, E&M Tie Line, and ISDN)
FF1-006: Serial Port Receive Data
FF1-009: SMDR Output Format
Hardware Requirements
A printer or external call accounting system is required to receive SMDR data.
Considerations
A call must be answered to generate SMDR data (e.g., answered by voice mail, call pickup, etc.)
You can specify which type of SMDR data format is sent (
i.e., either Format 1, 2, or 3
).
(SMDR Format #3 only) When a call is received from a non-ISDN line, the B channel entry is 
blank on the SMDR.
(SMDR Format #3 only) When a call is received from a H0(6B) / H1(24B,30B) ISDN line, the B 
channel is not shown on the SMDR.
The maximum number of characters allowed in the SMDR for a Caller ID Caller Name is 12. 
T1 Line
Description
The T-1 line provides up to 24 voice channels over a four-wire circuit. The 576 can support either 8, 
16, or 24 channels. When the card is set for 16 channels, it occupies two flexible card slots. When the 
card is set for 24 channels, it occupies three flexible card slots.
Unlike most other cards, the 576’s T-1 cards must be installed in selected flexible card slots. Up to 
three T-1 cards can be installed in a single cabinet, and a fully configured six-cabinet system can 
support up to 18 T-1 cards.
Hardware Requirements
Digital Service Unit (DSU)